LOQM Flashcards
What is the NSTM for L/O?
NSTM 262
What is the NSTM for Hydraulic Oil?
NSTM 245
What types of oil do we use?
- 23699
- 2190TEP
What are the sampling requirements for L/O?
- Within 24 hours prior to start.
- Daily while operating.
- Prior to transfer.
- When unusual operating conditions exist.
- After an equipment casualty.
- Test purifier discharge 30 minutes after starting and at least once every four hours.
What is the reference for L/O?
NSTM 626
What procedure is used when taking a L/O sample?
PMS Card 2000 R-1, R-2W.
What is the reference for Hydraulic Oil?
NSTM 245
What procedure is used when taking H/O sample?
2451 R-1W
What does TEP stand for?
Turbine Extreme Pressure
What is the criteria for the L/O sample?
Clear and Bright
What if the MRG L/O sample is UNSAT?
Source of contamination must be identified and L/O purified within 48 hours.
If source is not found within 48 hours, equipment must be secured.
If equipment must be operated CO’s permission is required and a DFS must be submitted.
What equipment has online purification L/O?
MRG
CRP
What equipment has offline purification L/O?
Line Shaft Bearings
LPACs
HPACs
What are the BS&W limitations for offline purification?
0.4% warning conditions
What are the BS&W standards for CPP?
Performed weekly
0.4% purify as many hours a day as possible, submit tech assist, major contamination of oil.