TQ Gas Flashcards
Which type of burner is commonly used in a domestic hot water tank?
Up-shot
What is the minimum passageway dimensions required to access a gas appliance?
36” x 36”
What is the minimum access opening required to access the space a gas appliance is located within?
24” x 30”
What are the testing requirements for welded gas piping?
(underground gas line, metal riser has one welded joint)
50 psig or 1.5 times the max operating pressure for 3 hours
What is the minimum dimension a pool heater can be located from a property line?
18”
The heat anticipator should be set to match what;
A) Control circuit amperage
B) Manufacturers gas valve amperage
C) Control circuit resistance
D) A or B above
D) A or B above
What is the minimum distance required from a source of ignition in a repair garage?
54”
What is the minimum distance required from a source of ignition in a storage garage?
18”
What percentage must the vent sizing table capacity be reduced when installing a corrugated liner?
A) 10%
B) 15%
C) 20%
D) 25%
C) 20%
Which flame detection method listed below utilizes energy light waves?
A) Intermittent
B) Ionization
C) Ultraviolet
D) Thermoelectric
C) Ultraviolet
What is the minimum dimension required for unthreaded portion of piping penetrating a finished floor?
2”
What is the minimum dimension required for unthreaded portion of piping penetrating a wall or ceiling?
1”
How is a heat anticipator wired in a controlled circuit?
Series
Ideal combustion
Same as perfect combustion, NO EXCESS AIR
CO2, N2, H2O, Heat and Light
Complete combustion
Has excess air
CO2, N2, H2O, O2, Heat and Light
Limits of flammability of natural gas
5% - 15%
Limits of flammability of propane gas
2% - 10%
On a 120 VAC circuit, what is the condition of a closed switch with 3 VAC measured across the switch contacts?
The switch is within acceptable limits (3% max)
Minimum combustable clearance required above a space heater?
36”
What is the COMBUSTION CHAMBER draft tolerance for a balanced draft system?
A) -0.02” to -0.04” wc
B) -0.2” to -0.4” wc
C) 0.02” to 0.04” wc
D) 0.4” to 0.6” wc
D) 0.4” to 0.6” wc
What is the VENT draft tolerance for a balanced draft system?
A) -0.02” to -0.04” wc
B) -0.2” to -0.4” wc
C) 0.02” to 0.04” wc
D) 0.4” to 0.6” wc
A) -0.02” to -0.04” wc
What is the minimum dimension a gas appliance vent can terminate above a paved sidewalk or paved driveway located on a public property?
7 feet
Difference between type BH vent systems and type BW vent systems?
Corrosion resistance
How many hours would a burner firing propane operate with a rated input of 8855 BTU’s if it were connected to a properly filled 30lb cylinder?
A) 32 hours
B) 58 hours
C) 72 hours
D) 84 hours
C) 72 hours
30 lbs x 8.5 CF/lb = 255 CF
255 CF x 2500 BTU/CF = 637,500 BTU
637,500 BTU / 8855 BTU/hr = 72 hours