Gas RED SEAL Flashcards
what is the maximum pilot input?
3% of total input in BTU
Which procedure would be used to measure manifold pressure?
remove outlet screw, screw in adaptor, connect manometer and turn on gas.
Which appliance listed below cannot use a double-acting barometric damper?
Incinerator
how would a totally blocked vent affect operation of a gas regulator?
the pressure would increase
A combustion fan receives an output signal from a/an:
electronically commutated motor ECM
how is a flare fitting tightened?
wrench and no pipe dope
how is draft verified on a draft hood?
a smoke pen before the draft hood
the expected voltage measured between the “L1” and “R” terminals on a conventional furnace with the secondary voltage grounded to the earth ground would be:
96 volts
Whats is the limit of the CO gas in a dwelling
5 ppm
what is the positive pressure relief setting required for a system supply pressure of 2 psig and an appliance rating of 30” wc?
30 “w.c.
Burner output calculation?
efficiency?
3600/ avg rev per minute x gauge size x CV = Output
% x output - output = efficiency
when can pipe be re-used?
after being inspected, cleaned and tested.
What is the maximum reading on a test gauge for a 50 psig pressure test?
200 psig
which is not allowed to be installed?
a domestic gas fired clothes dryer in a bathroom
LOOK up PROPANE FILL NUMBERS
what would happen if the high limit actuates in a boiler system?
cuts power to gas valve
With direct reference to the electrical measurements below, what device is faulty?
i. open circuit test: 20 mv DC
ii. closed circuit test: 12 mv DC
iii. dropout test 6: mv DC
Thermocouple
what method is used to seal polypropylene pipe?
gasket
what is the maximum distance between identification labels on a residential copper gas line:
6 feet
what is the minimum height a b vent can terminate above a sloped roof with a 16/12 pitch?
6.5 feet
what is the minimum distance required between a direct vent and a combustion air hood?
3 feet
what steps are required to prepare piping for a mechanical compression joint?
cut, ream, bevel, and mark
what schedule pipe is required for liquid propane?
schedule 80
what size outlet is required for an unknown future connection with a 1-1/4” pipe size downstream of a regulator?
1-1/4”
FULL SIZE
what would best describe a document required when adding components to a heating system?
As built drawings
what is the problem if the furnace high limit continues to activate during a call for heat?
Dirty filter
what is the dirt pocket size for a 4000,000 btuh pool heater with a 3” pipe?
2”
what is the minimum time required to pressure test 280 feet of gas line operating at 50 psig?
3 hours
propane tanks are inspected by?
provincial boiler pressure vessels branch
what is the minimum appliance combustible clearance from a source of ignition in a storage garage?
18”
when performing combustion analysis on a natural draft gas fired furnace with an output of 325000 BTUH what is the maximum allowable measurement for CO
400 PPM