Red seal 3 Flashcards
what is the manganese green sand filter used for:
to remove ferrous iron, manganese and hydrogen sulphide.
A wet stand pipe system requires which CCC device, when pipes are not susceptible to freezing?
DCVA
which is the first take off on common water service system?
fire sprinkler
the minimum vent height for a RV dumping station is in meters:
2m
when sizing a water softener, how many gallons are consumed by 4 people in a house?
240
what type of waste does a sterilizer give off?
acidic
what’s the minimum size water supply to a urinal flush tank?
3/8”
whats the minimum pipe size for a medical gas piping?
1/2”
hydrogen sulphide is removed by?
manganese zeolite filters, aeration, and chlorination.
an activated carbon filter removes?
Taste and odour
iron can be removed by?
water softener
polyphosphate
Iron filler
what is a maintenance bond purpose?
to ensure good workmanship
What is the name of the quick connect adaptor used on a well system with series 160 PE piping?
Pitless adaptor
the flow from a wash down ventilation pump into a drainage system is taken as:
1L/s =31.7Fus
what is draw down?
the measured depth that water in the well lowers when the well is being pumped (used).
if a pipe from the well to the house is not graded properly:
its difficult to maintain pressure and prime the pipe
on a wall hung water closet, the distance from the face of the wall to the bowl is set by:
back up nuts and washers
A PVB is installed how high above the critical level?
12”
every acid waste trap, must have a water seal of at least:
2”
the minimum size of the water distribution pipe in a building is:
1/2”
the minimum protection used when incorporating a pre-rinse sink would be:
An AVB (atmospheric vacuum breaker)
Every oil interceptor, shall be provided with vents that:
extend to open air
connect to the interceptor at opposite ends
terminate at elevations differing by not less than 300mm (12”)
A cleanout for a trap, which serves a leader or a sub-soil drain is installed:
over the trap upstream of the trap
one trap may serve a group of floor drains, showers or laboratory sinks provided:
all fixtures must be in the same room
What is installed on a centrifugal pump to prevent the water from draining backwards?
Check Valve
to lower the PH you need to use:
a Neutralising filter
The maximum number of flushometer WCs, that can discharge into a 80mm (3”) stack is:
6 WCs
How many RWLs are required for a 40 m x 40 m roof, that uses flow controlled roof drains.
(rainfall intensity is 20mm per 15 mins.)
2
why is there salty water after the regenration cycle on a water softener?
the rinse cycle is too short
All the waste openings that serve a 3 compartment sink are 1 1/1’ what is the minimum size of trap?
2” (2.4.9.3. [2] )
what is required when installing long, straight horizontal or vertical runs of copper domestic hot water piping?
expansion joints
the rule for air breaks sizing:
1” or the same pipe diameter