How wires are configured in relation to the terminals is known as ______.
Lead dress
What standard is used as an advisement for wire tinning, the amount of allowable bare insulation, the lead dress for the wires attached to the terminal, and the amount of wire wrap around the terminal.
J-STD-001C
What is the name of this type of terminal?
The turret terminal
What is the name of this type of terminal?
The bifurcated terminal
Wires attached to turret terminals are formed around the terminal at least _____ degrees but no more than ____ degrees.
Wires attached to turret terminals are formed around the terminal at least 180° but no more than 270°.
The minimum 180° form assures good mechanical strength, while the maximum 270° form allows easier field repairs.
Wires are wrapped on the pins of the bifurcated terminal. The acceptable range of the wrap is between _____ degrees and _____degrees.
Wires are wrapped on the pins of the bifurcated terminal. The acceptable range of the wrap is between 90° and 180°.
What is the name of this type of terminal?
The hook terminal
Like the turret terminal, the wires attached to the hook terminal should be wrapped around the hook between ____ and _____ degrees.
Like the turret terminal, the wires attached to the hook terminal should be wrapped around the hook between 180° and 270°.
What is the name of these types of terminal?
The pierced and cup terminals
The wire wrapping of a pierced terminal should be at least ___ but no more than _____ degrees.