TechSpec Chapters Flashcards

1
Q

What is TechSpec 3.1.1?

A

Shutdown Margin - RTCBs Open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is TechSpec 3.1.2?

A

Shutdown Margin - RTCGs Closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is TechSpec 3.1.3?

A

Reactivity Balance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is TechSpec 3.1.4?

A

Moderator Temperature Coefficient

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is TechSpec 3.1.5?

A

CEA Alignment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is TechSpec 3.1.6?

A

Shutdown CEA Insertion Limits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is TechSpec 3.1.7?

A

Regulating CEA Insertion Limits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is TechSpec 3.1.8?

A

Part Strength CEA Insertion Limits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is TechSpec 3.1.9?

A

Special Test Exception - Shutdown Margin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is TechSpec 3.1.10?

A

Special Test Exception - Modes 1 and 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is TechSpec 3.1.11?

A

Special Test Exception - Reactivity Coefficient Testing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is TechSpec 3.2.1?

A

Linear Heat Rate (LHR)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is TechSpec 3.2.2?

A

Planar Radial Peaking Factors (Fxy)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is TechSpec 3.2.3?

A

Azimuthal Power Tilt (Tq)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is TechSpec 3.2.4?

A

Departure from Nucleate Boiling Ratio (DNBR)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is TechSpec 3.2.5?

A

Axial Shape Index (ASI)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is TechSpec 3.3.1?

A

RPS Instrumentation - Operating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is TechSpec 3.3.2?

A

RPS Instrumentation - Shutdown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is TechSpec 3.3.3?

A

Control Element Assembly Calculators (CEACs)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What is TechSpec 3.3.4?

A

RPS Logic and Trip Initiation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is TechSpec 3.3.5?

A

ESFAS Instrumentation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is TechSpec 3.3.6?

A

ESFAS Logic and Manual Trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is TechSpec 3.3.7?

A

Diesel Generator (DG) - Loss of Voltage Start (LOVS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What is TechSpec 3.3.8?

A

Containment Purge Isolation Actuation Signal (CPIAS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

What is TechSpec 3.3.9?

A

Control Room Essential Filtration Actuation Signal (CREFAS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

What is TechSpec 3.3.10?

A

Post Accident Monitoring (PAM) Instrumentation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

What is TechSpec 3.3.11?

A

Remote Shutdown System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

What is TechSpec 3.3.12?

A

Boron Dilution Alarm System (BDAS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

What is TechSpec 3.4.1?

A

RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

What is TechSpec 3.4.2?

A

RCS Minimum Temperature for Criticality

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

What is TechSpec 3.4.3?

A

RCS Pressure and Temperature (P/T) Limits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

What is TechSpec 3.4.4?

A

RCS Loops - Modes 1 and 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

What is TechSpec 3.4.5?

A

RCS Loops - Mode 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

What is TechSpec 3.4.6?

A

RCS Loops - Mode 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

What is TechSpec 3.4.7?

A

RCS Loops - Mode 5, Loops Filled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

What is TechSpec 3.4.8?

A

RCS Loops - Mode 5, Loops Not Filled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

What is TechSpec 3.4.9?

A

Pressurizer

38
Q

What is TechSpec 3.4.10?

A

Pressurizer Safety Valves - Modes 1, 2, and 3

39
Q

What is TechSpec 3.4.11?

A

Pressurizer Safety Valves - Mode 4

40
Q

What is TechSpec 3.4.12?

A

Pressurizer Vents

41
Q

What is TechSpec 3.4.13?

A

Low Temperature Overpressure Protection (LTOP) System

42
Q

What is TechSpec 3.4.14?

A

RCS Operational Leakage

43
Q

What is TechSpec 3.4.15?

A

RCS Pressure Isolation Valve (PIV) Leakage

44
Q

What is TechSpec 3.4.16?

A

RCS Leakage Determination

45
Q

What is TechSpec 3.4.17?

A

RCS Specific Activity

46
Q

What is TechSpec 3.4.18?

A

Steam Generator (SG) Tube Integrity

47
Q

What is TechSpec 3.5.1?

A

Safety Injection Tanks (SITs) - Operating

48
Q

What is TechSpec 3.5.2?

A

Safety Injection Tanks (SITs) - Shutdown

49
Q

What is TechSpec 3.5.3?

A

ECCS - Operating

50
Q

What is TechSpec 3.5.4?

A

ECCS - Shutdown

51
Q

What is TechSpec 3.5.5?

A

Refueling Water Tank (RWT)

52
Q

What is TechSpec 3.5.6?

A

Trisodium Phosphate (TSP)

53
Q

What is TechSpec 3.6.1?

A

Containment

54
Q

What is TechSpec 3.6.2?

A

Containment Air Locks

55
Q

What is TechSpec 3.6.3?

A

Containment Isolation Valves

56
Q

What is TechSpec 3.6.4?

A

Containment Pressure

57
Q

What is TechSpec 3.6.5?

A

Containment Air Temperature

58
Q

What is TechSpec 3.6.6?

A

Containment Spray System

59
Q

What is TechSpec 3.7.1?

A

Main Steam Safety Valves (MSSVs)

60
Q

What is TechSpec 3.7.2?

A

Main Steam Isolation Valves (MSIVs)

61
Q

What is TechSpec 3.7.3?

A

Main Feedwater Isolation Valves (MFIVs)

62
Q

What is TechSpec 3.7.4?

A

Atmospheric Dump Valves (ADVs)

63
Q

What is TechSpec 3.7.5?

A

Auxiliary Feedwater (AFW) System

64
Q

What is TechSpec 3.7.6?

A

Condensate Storage Tank (CST)

65
Q

What is TechSpec 3.7.7?

A

Essential Cooling Water (EW) System

66
Q

What is TechSpec 3.7.8?

A

Essential Spray Pond System (ESPS)

67
Q

What is TechSpec 3.7.9?

A

Ultimate Heat Sink (UHS)

68
Q

What is TechSpec 3.7.10?

A

Essential Chill Water (EC) System

69
Q

What is TechSpec 3.7.11?

A

Control Room Essential Filtration System (CREFS)

70
Q

What is TechSpec 3.7.12?

A

Control Room Emergency Air Temperature Control System (CREACTS)

71
Q

What is TechSpec 3.7.13?

A

Engineered Safety Feature (ESF) Pump Room Exhaust Air Cleanup System (PREACS)

72
Q

What is TechSpec 3.7.14?

A

Fuel Storage Pool Water Level

73
Q

What is TechSpec 3.7.15?

A

Fuel Storage Pool Boron Concentration

74
Q

What is TechSpec 3.7.16?

A

Secondary Specific Activity

75
Q

What is TechSpec 3.7.17?

A

Spent Fuel Assembly Storage

76
Q

What is TechSpec 3.8.1?

A

AC Sources - Operating

77
Q

What is TechSpec 3.8.2?

A

AC Sources - Shutdown

78
Q

What is TechSpec 3.8.3?

A

Diesel Fuel Oil, Lube Oil, and Starting Air

79
Q

What is TechSpec 3.8.4?

A

DC Sources - Operating

80
Q

What is TechSpec 3.8.5?

A

DC Sources - Shutdown

81
Q

What is TechSpec 3.8.6?

A

Battery Cell Parameters

82
Q

What is TechSpec 3.8.7?

A

Inverters - Operating

83
Q

What is TechSpec 3.8.8?

A

Inverters - Shutdown

84
Q

What is TechSpec 3.8.9?

A

Distribution Systems - Operating

85
Q

What is TechSpec 3.8.10?

A

Distribution Systems- Shutdown

86
Q

What is TechSpec 3.9.1?

A

Boron Concentration

87
Q

What is TechSpec 3.9.2?

A

Nuclear Instrumentation

88
Q

What is TechSpec 3.9.3?

A

Containment Penetrations

89
Q

What is TechSpec 3.9.4?

A

Shutdown Cooling (SDC) and Coolant Circulation - High Water Level

90
Q

What is TechSpec 3.9.5?

A

Shutdown Cooling (SDC) and Coolant Circulation - Low Water Level

91
Q

What is TechSpec 3.9.6?

A

Refueling Water Level - Fuel Assemblies

92
Q

What is TechSpec 3.9.7?

A

Refueling Water Level - CEAs