RD: Radioactive Drains Flashcards
What is the power supply for the RD pumps?
NH
What is the Safety Basis for the RD system?
Not Interconnected w/o check valves
Each ESF Sump has backflow check valves
RD pumps are _______ % capacity.
100%
How are the RD pumps physically attached to their sumps?
They are hung from the sump cover plate and protected by a pipe.
Where does the RD System ultimately send any water it collects?
To the Liquid Radwaste System
High level in a RD sump starts the _______ pump.
Lead
High-High level in a RD sump starts the _______ pump.
Lag
Lo-Lo level in a RD sump does what?
Secures all operating sump pumps
____ supplies lube water to the RD Sump Pumps.
DW
To where do the Reactor Cavity Sump Pump discharge?
To the Containment East Sump
How many pumps does each Containment Sump have?
1
What must be open to start a Containment Sump Pump?
UV-23
What is the time delay associated with an auto start of a Containment Sump Pump?
3 minutes after receipt of a High Level
What type of valve is RDA-UV-23?
MOV
What type of valve is RDB-UV-24?
AOV