Systems - Fire Protection Flashcards
Is it necessary to test the fire detection/protection systems during preflight?
Why not?
No because it is self testing every flight
What type of fire detection is used in the cargo pits?
Smoke detectors
Is a cargo fire a recall item?
No
How many fire bottles are in the cargo fire protection system?
5
When fighting a cargo fire, in what sequence are these bottles employed?
- 2 bottles are deployed immediately
- 3 start metering after 20 minutes.
If the plane lands prior to the 20 minutes
* one bottle blows on landing.
If the plane is on the ground
* 1 bottle blows after 20 minutes
What happens in the equipment cooling system when the forward cargo fire switch is armed?
Goes into override.
* Shuts down all the recirc fans
* turns off cargo heat in forward cargo compartment
* commands pack to supply air into cockpit and supernumerary area
* turns off the nitrogen generation system
* vents the air through the E/E bay to the forward outflow valve
After fighting a cargo fire would you expect to see the EICAS warning message go away if the fire is extinguished?
Not right away as the smoke detectors take time to distinguish between smoke and halon
What precaution must be taken when using Halon?
Use a PBE
What does the APU BTL DISCH light indicate?
Bottle has been discharged and/or the bottle pressure is low
How many fire extinguishers for the APU?
1 bottle
How many Loops on the APU?
2
Can the APU bottle be discharged without an indication of a fire?
Yes as it is on the HOT batt bus
Name as many engine fire indications as you can.
- EICAS MSG
- engine fire switch lights
- fuel control switch lights
- aural bell
- master warning on glareshield
Name automatic actions when engine fire handle pulled.
- bleed is closed
- engine driven hyd pump is depressurized
- hyd fluid is shutoff
- engine driven electric generator is tripped
- fire bottle squibs arm
- isolates affected engine thrust reverser
Name automatic actions when APU fire handle pulled.
- bleed is closed
- electric generator is tripped
- APU inlet door is closed
- in unattended mode discharges the fire bottle