Strip Mall Fires Flashcards
Define Non-combustible
CMU or concrete tilt-up construction. Roof has open web truss and the roof is composed of metal decking. Partition walls have metal studs covered by sheet rock.
What is the size of a modern strip mall room?
20-30 feet wide and 75-100 feet deep with a ceiling height of 12-16 feet.
What size of lines should be used on strip mall fires with significant fire?
2 1/2 inch or master streams.
How many GPM of water may be needed for a medium size strip mall fire? What if there is fire above drop ceiling?
1000 GPM
Add additional 1000 GPM for drop ceiling
What is the greatest hazard at modern strip mall fires (1970s and later)?
Early Roof Collapse
What are signs of probable roof collapse?
Advanced fire conditions in an occupancy
Fire involvement in two or more occupancies
Hot, rising smoke from cockloft vents (turbine vents)
Fire venting from roof
Roof sag
What does the ADULTS acronym stand for?
Advanced fire
Defensive Operations
Unable to identify location or extent of the fire
Large, un-compartmented spaces
Tons of Water
Stand Pipe operations
These are the scenarios in which 2.5 inch should be considered as a primary attack line.