Set 7 Flashcards
- 0PGP03-ZA-0098 Station Housekeeping*
- *
If an item is stored in a seismic II/I area, what must be done?
Tie the item down securely
Seismic II/I area: Class II component can affect a class I component during an earthquake.
- 0PGP03-ZA-0098 Station Housekeeping*
- *
In order to eat or drink in a house keeping area, what must the area be zoned as?
Zone V
Zone IV is the same except no eating or drinking allowed in Zone IV. (MAB, FHB, ECW, etc.)
Note:
Zone I is the highest degree of cleanliness (Clean room)
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
Who is responsible for determining if it is safe to enter a confined space?
Entry Supervisor
- 0PGP03-ZA-0098 Station Housekeeping*
- *
Who approves exemptions for station housekeeping?
Plant Manager
- 0PGP03-ZA-0098 Station Housekeeping*
- *
How many drains in the RCA may be taped up for your work area?
≤ 1 drain at a time
Do not leave unattended.
Note:
If done long term, do a T-MOD
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
What is the definition of a confined space?
Large enough someone can enter
Limited entry / exit points
Not designed for continuous occupancy
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
How many controlled Entry and Exit points will be established for a Permit entry Space?
1 Entry
Can have multiple exits
- PGP03-ZO-9900 Operability Determinations and Functionality Assessments Program*
- *
How often must the bases be reviewed for OPERABLE but degraded or nonconforming conditions?
Quarterly
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
A permit required confined space requires continuous atmospheric monitoring. How is this achieved?
Personal Monitor
Calibrated Monitor is inserted into space
Calibrated monitor outside space but with a tube inside space
- 0PGP03-ZE-0004 Plant Surveillance Program*
- *
What must be done if a SR is interrupted and that interruption extends past shift change?
Suspend the SR
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
Is a retrieval harness required to be worn?
Yes, unless it adds to overall risk and interferes with rescue efforts.
Can use ankle or wrist bracelets with permission of the Industrial Safety Group
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
What O2 % would be considered safe in regards to Confined Spaces?
20% - 22%
Permit entry confined space: 19.5% - 23.5%
Note:
For permit entry confined space, Flammable gas ≤ 10% of the LEL
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
Who should be contacted to determine if the atmosphere of the space to be entered is connected to any system capable of INERTING the space being entered?
Operations
- 0PGP03-ZE-0004 Plant Surveillance Program*
- *
Who must the test coordinator inform once the SR is completed, suspended, or has failed?
Shift Manager
Test coordinator will forward results to the surveillance scheduler.
- 0PGP03-ZI-0007 Confined Space Entry Program*
- *
What is the definition of a permit required confined space?
Contains or has potential to contain a hazardous atmosphere
Contains a material that can potentially engulf entrant
Has internal configuration that could possibly trap the entrant
Contains any other health or safety hazard