  • 0PSP03-XC-0002 Initial Containment Inspection*
    • *

What is the purpose of 0PSP03-XC-0002 Initial Containment Inspection to Establish Integrity?

A
  • *Visual Inspection to ensure no loose debris present**
  • Could clog emergency sump strainers during LOCA*

Verify 48” containment purge valves closed

Verify 18” Supplementary purge valves open/closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • 0PSP03-XC-0002 Initial Containment Inspection*
    • *

Who can perform the initial containment inspection to establish integrity?

A

SRO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • 0PSP03-XC-0002 Initial Containment Inspection*
    • *

What is the max occupancy of containment during normal operations?

A
  • *72 people**
  • PAL and AAL must be OPERABLE*

Normal Operations is MODE 1 - 4 (Doors normally closed) or MODE 5 with the doors closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  • 0PSP03-XC-0002A Containment Entry (Integrity Established)*
    • *

Who can perform all sections of this surveillance with exception of closing out the surveillance?

A

Non-Licensed work control SRO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • 0PSP03-XC-0002A Containment Entry (Integrity Established)*
    • *

Who determines what tools, test equipment, or other material may be left inside the RCB once personnel exit containment with integrity established?

A

SM / Unit Supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • 0PSP03-XC-0002A Containment Entry (Integrity Established)*
    • *

If a Øa occurs while personnel are in containment, where should personnel evacuate?

A

Aux Air Lock

If Aux Air Lock unavailable, must reset Øa and open the PAL OCIV. Personnel can then exit via the PAL.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • 0POP01-ZA-0001 Admin Guidelines*
    • *

While checking the position of a normally locked closed valve, the valve operator cannot be moved due to the locking device. What is the proper method for checking the position of this valve?

A

Remove the locking device

Check valve in closed direction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  • 0POP01-ZA-0001 Admin Guidelines*
    • *

When is Independent Verification NOT required?

A

Changing position does not render component incapable of performing it’s safety function

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  • 0POP01-ZA-0001 Admin Guidelines*
    • *

How is a locked throttle valve’s position verified?

A

Visual Observation

Local Indicators

SM’s permission required to move locked throttle valve.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  • 0POP01-ZA-0001 Admin Guidelines*
    • *

When are valves in the AFWST pit required to be checked?

A

If security barrier is breached

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
  • 0POP01-ZA-0001 Admin Guidelines*
    • *

Following an outage, whose permission is needed to waive the initial valve lineup for a system?

A

Unit’s Operation Manager

One of the following conditions must exist:

  • System has remained in service
  • No work performed on system and system not modified
  • If work performed, then process was controlled by ECO process

Note:
Valves in MAB pit rooms not required to be checked for initial valve lineups

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
  • 0POP01-ZQ-0022 Plant OPS Shift Routine*
    • *

If multiple channels are not available for a channel check, what must be done?

A

Compare indicated value with data obtained from previous log

Channel check compares channel’s indication with other indications monitoring the same parameter.

  • Has nothing to do with acceptance criteria.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
  • 0POP01-ZQ-0022 Plant OPS Shift Routine*
    • *

Who reviews the safety function checklist?

A

Unit Supervisor

On-coming RO completes the safety function checklist

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
  • 0POP01-ZQ-0022 Plant OPS Shift Routine*
    • *

How far back in the logs should the on-coming watchstanders review?

A

Whichever is less:

Since last watch
OR
Prior 72 hrs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
  • 0POP01-ZQ-0022 Plant OPS Shift Routine*
    • *

Who ensures appropriate entries are made in the control room logbook?

A

Unit Supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q
  • 0POP01-ZQ-0022 Plant OPS Shift Routine*
    • *

Who approves the use of temporary logs?

A

Unit Supervisor
OR
Shift Manager

17
Q
  • 0PSP03-ZQ-0028 Operator Logs*
    • *

If ECW supply temperature is < 75 ˚F and temperature lowers by ≥ 4 ˚F between consecutive log readings, what must the operator do?

A

Start all ECW pumps

18
Q
  • 0PSP03-ZQ-0028 Operator Logs*
    • *

What leakage rate would force the you to declare the containment sump level / flow monitoring system inoperable?

A

> 4.7 gpm

19
Q
  • 0PSP03-ZQ-0028 Operator Logs*
    • *

If AFD alarm has been inoperable for > 24 hrs, how often must AFD be logged?

A

Every 30 mins