in order to determine the absorption qualities of soils for a proposed disposal field, code requires that the proposed site be:
subjected to a percolation test
the minimum sidewall of a seepage pit shall be at least
10 feet below the inlet
what is the minimum gallon capacity for a septic tank
750 gallons
the minimum liquid capacity of a septic tank serving 2 bedrooms 3 bath residence is
750 gallons
effluent or drainage from a home clothes washing machine may be disposed of by drainign
through a sanitary system connected to a septic tank
no cesspool, septic tank, seepage pit or drainfield shall be connected to any public sewer or to any building sewer leading to such public sewer (T/F)
true
a four inch concrete pad shall be poured around the well casing and shall extend ____ inches on all sides
18
maximum length of a single tile drainfield lateral shall be ____ feet
100
where distribution drain lines in leaching beds are used, the maximum distance between centers of distribution lines shall not exceed:
6 feet
where distribution drain lines in leaching beds are used, the minimum distance between centers of distribution lines shall not exceed
4 feet
a cesspool is 48 inches in diameter and 20 feet deep. if filled to the top with water the volume in gallons would most nearly be
1880
according to code, a septic tank cannot be installedcloser than ____ feet to the building water supply service.
5 feet
the liquid capacity of all septic tanks for dwelling units is determined by the number of
bedrooms
a septic tank for a 4 bedroom house must have a capacity of at least ____ gallons
1200
cast-in-place septic tanks located in a parking lot shall be designed to support the anticipated load but not less than that of a
ten ton truck
the minimum distance from a drainfeild to a basement wall shall be ____ feet
8
the minimum air space within a septic tank is
9 inches
residential septic tanks
shall be rectangualr in shap
the disposal feild line is sized by what
-septic tank size
-type of soil
-waste flow rate
a concrete septic tank shall be protected from corrosion by bituminous coating extending ____ inches below the water line
4