Section 8-Manuf & Mobile Homes and Min Fixtures Flashcards
For sewers on M&M homes, cleanouts shall be provided at intervals not to exceed for main and branch sewers _____. Cleanout shall extend to ________ with _______pipe and provided with a ________. ________ shall be provided around each cleanout
100ft
6in and smaller
grade
CI, Sch40 PVC or ABS
cleanout plug
4in concrete pad 18insq
Each M&M shall be provided with a __________ sewer
4in sewer
For M&M sewers, All main and branch sewers ________ shall not require cleanouts but __________ at intervals not to exceed ________ as well as in all ______.
8in and larger
standard manholes
400ft
changes in direction
on M&Ms, A ____waste connection shall be provided and extended ________using a ______.
3in
1in above grade
3in standard female thread
A _________________ shall be provided around the waste opening and a _______ shall be fastened by ________ to the concrete pad
4 in concrete pad 24in sq
3in screw plug
chain
Waste pipe connection between M&M and sewer opening shall be made of
CI, sch40 steel, ABS, PVC, or copper pipe
All waste piping that does not have at least 18in cover shall be _____
CI pipe
An individual water connection to M&M shall consist of…
consist of riser terminating 4 in above ground with min 2, 3/4 in valve
for MM, A ___________ shall be provided and accessible for ______ water and ________l out with screw connection for the following:1 valve outlet for _______ and one valve outlet for _________
frost proof hydrant
lawn / fire control
home water system
lawn/ fire control
Riser pipe for MM shall be __________ and ________. An ________ shall encase both outlets but not prevent _______ during freezing weather.
graded to divert surface drainage
encased in 8in vitrified clay pipe or equiv with space for insulation
insulated cover
connection
All types of buildings shall be provided with ____ on each level or floor unless _______
toilet rooms
separate facilities on each level are unnecessary
or every other level shall be sufficient
Toilet rooms for males, females, and unisex shall be______
clearly marked
one ________ shall be required on each floor of a public building unless otherwise approved by the dept.
service sink
A urinal may be substituted for a WC for males if they do not exceed ____ the number of required WC for males.
1/3
Sanitary facilities shall be provided for the public if the building contains __________
5,000 sqft or more
If 2 or more fixtures that receive human waste are installed and a wood floor is not used, the toilet room shall have at least:
one floor drain and one accessible hose bibb
In licensed food establishments, handwashing sinks shall have a min hot water temp of ________ and max temp of _______. Self closing faucets shall provided flow for no less than ______ seconds. And placement of sinks shall be approved by __________.
100
120
15
Cabinet for Health and Family Service, Dept for Public Health
In licensed food establishments, a _________is required for washing utensils and shall be plumbed _______. A dishwashing or ware machine shall discharge ______ through a ________. A residential dishwasher shall discharge _________ or ___________
3 comp sink
directly
indirectly/ 3in open receptacle
through an air gap device or indirectly through 3in open receptacle
Sinks solely used for food prep shall discharge
by indirect connection to min 3 in trap
All hub drain, open receptacles, floor sinks or other waste receptacles shall extend _______ unless
1in above floor plane unless a full grate or strainer is installed flush with the floor
If more than 5 persons are employed, _________shall be provided
separate facilities for each sex
A private bath attached to a private room shall have
1 WC, one lav, and bathtub or shower
A gang sink ____ is equal to 1 lav
24 in
A circular sink _____is equal to 1 lav
18 in
A urinal trough _____ is equal to 1 urinal
24in