Section 7-House Sewers and Storm Water Flashcards

1
Q

DWV and plumbing system that is new shall be ________ and _____ of other buildings and the building shall have a(n) ____________ connection with the sewer

A

separate and independent
independent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A building sewer may serve addition buildings and still be considered as one sewer if the additional buildings are

A

used in conjunction with the primary, contained within the same deed as primary, restricted within the deed form being sold separately as primary building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

An excavation for a sewer shall be _______ work and shall be _________ until

A

open trench work, kept open, it has been inspected, tested, and approved

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The sewer shall be at a _______depth to ______

A

sufficient, properly serve a plumbing connection installed in the basement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A house sewer shall be laid on a grade of

A

not less than 1/8 in nore more than 1/4 per foot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A sewer shall have at least ______ of cover

A

18in

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Sewer piping installed under property subject to vehicular traffice) shall have at least _______ of cover unless

A

24 in
sch 40 or 80 cast iron encased in a min 6in of concrete on each side and top and covered to prevent direct contact with concrete

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Sewer shall be backfilled by hand and _________

A

tamped 6in above or filled with 6in grillage above.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If less than 18 in of cover is available what should be done

A

a request for a variance submitted to the division in writing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A house sewer or combined sewer shall be made of ….

A

extra heavy and service weight CI, vitrified clay, concrete, PVC or ABS, Cell core PVC or ABS, Truss pipe, extra heavy SDR 35, type PS 46, PVC sizes 4in-15in, PVC ribbed and coextruded composite, PE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A storm sewer inside a building extending 2ft outside in sizes 8in and smaller shall be made of

A

CI, aluminum, sch 40 ABS or PVC DWV pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A storm sewer size 10in or larger shall be made of

A

CI, aluminum, schedule 40 ABS or PVC DWV pipe, SDR 35, vitrified clay or contrete, PE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Roof drain shall have _______ extending not less than _____ above the surface of the roof immediately adjacent to the roof drain and shall be no less than ______ the area of the conductor or leader

A

strainers, 4 in
1.5 X

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Roof drain strainer on _____________ may be of the flat surface type, installed ____ with the deck , with inlet area not less than _____ the area of conductor or leader

A

sun decks, parking decks or similar
level
2X

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Secondary (emergency) roof drains shall be provided where and what is required for them

A

the roof perimeter construction allowing ponding if primary roof drains become blocked
requirements: piping and point of discharge separate from primary, discharge above grade plane in location normally observed by building occupants or maintenance personnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Primary and secondary roof drains shall be sized according to

A

size of storm systems table

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Change of direction of a sewer shall be made only with

A

long curves, 45 wyes, half wyes, quart, sixth, eighth, 16th bends or sanitary tees in on back or side but not more than 45 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Minimum size of a house sewer

A

4in nor less than that of house drain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

A storm sewer shall not be laid paralell to or within ___ft of a ______

A

2, bearing wall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

A storm sewer shall be laid at sufficient depth to protect it from

A

freezing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Combined house drain or sewer shall not be less than _____

A

4in and not smaller than required for same FU’s or same roof area in seperate systems

22
Q

For building after Aug 1 1996, each plumbing fixture or opening connecting to combo sewer shall either be installed __________ or discharge _________

A

above elevation of the cover of nearest manhole serving the main
through a sewage ejector to the combo sewer system at an elevation high enough to prevent flooding of the building

23
Q

A house sewer laid in undisturbed ground shall be laid at on at least ______

A

4in pea gravel, sand, or other approved grillage

24
Q

A storm sewer laid in undistributed ground requires

A

no grillage

25
Q

Storm or house sewer laid in filled ground shall__________

A

be embedded to lower quadrant with at least 4in concrete pad below invert or other equivalent

26
Q

A support filled in ground shall be on a ______center to a solid footing, either undisturbed earth or rock

A

10ft

27
Q

A house sewer constructed of flexible thermoplastic shall be installed with at least

A

6in of gravel on all sides

28
Q

In a public building, where whole or part of building drain/DWV is below level of sewer main, waste shall be __________

A

lifted according to sump/receiving tank requirements or a vented ejector

29
Q

In a residential building with sewer level above basement floor, waste shall be lifted by means of and constructed how

A

an approved sump pump that is gas and air tight and constructed of poured or precast concrete, approved fiberglass or PE material

30
Q

A sump pit shall be provided with __ vent which can also ___

A

a 2in vent which can also be a waste and vent for laundry tray

31
Q

Sump pump discharge piping shall be _____ waste pipe extended ______

A

2in, inside the building to a least 12in above outside grade plan

32
Q

Sump pit shall be provided with _______

A

tight fitting concrete cover

33
Q

On the outside of the building, the waste piping [from sump pit] shall connect into a _______ and _____

A

4x2 sanitary tee connected to 4in trap and then into sanitary sewer
the tee at least 2in above finished grade plan and shall have ventilated cap

34
Q

A subsoil drain shall discharge into _____

A

an airtight sump or receiving tank located to receive sewage by gravity

35
Q

__________ or ________ shall lift sewage and discharge into house sewer

A

pump or ejector

36
Q

Sewage sumps shall be a min of ________ size and no less than ______ depth

A

24 in for both

37
Q

Sewage pump system that relies solely on a pump shall be equipped with

A

audible and visual alarm to be place in occupied space

38
Q

A sump shall discharge how

A

automatically

39
Q

A sewage ejector shall be vented with what size in residential? commercial or industrial? Exception

A

2in res
3in comm
Except in comm if 3 in vent stack serves a fixture that empties into ejector pit is less than 25ft away from pit a re vent with 2in back to 3in stack is acceptable

40
Q

The ejector vent shall not be smaller than

A

recommended by the manufacturer of the pump

41
Q

If a subsoil catch basin is installed below sewer level ______ shall be used and shall discharge into __________ or _________

A

automatic ejector
properly trapped fixture or into storm water drain

42
Q

A roof, paved area, court or courtyard shall be drained into

A

storm water, combo, or surface drainage area unless prohibited

43
Q

If a roof, paved area, court or courtyard drain is connected to combined sewer it shall be,

A

trapped (inside or below frost line) unless opening at top is more than 10ft from window, scuttle, air shaft

44
Q

Trap for roof, paved area, court(yard) drain shall be

A

set below frost line or inside the building

45
Q

Conductor or roof leader in the building or interior court or vent pipe shaft shall be contructed of

A

CI, Galv iron, Galv steel, copper, Schedule 40 ABS or PVC DWV, resin

46
Q

PVC or ABS for conductors or leaders shall be limited to buildings with conductor not exceeding _______ in height unless _________

A

45ft
certain ASTM stamps for piping, install is made per manufacturer’s recommendations (and can prove) and firestop systems inspected by approved inspection agency

47
Q

If outside sheet metal conductor or downspout is connected to house drain it must be with

A

a CI pipe extending vertically at least 1ft above grade plane

48
Q

A conductor pipe shall not be used as a ______ pipe

A

DWV or vice a versa

49
Q

Overflow pipe shall connect how with house sewer, drain or waste pipe

A

indirectly

50
Q

The ejector vent shall not be smaller than

A

recommended by the manufacturer of the pump

51
Q

A subsoil drain below sewer level shall discharge into ___________ and shall be ______________ into the _____________or ________________.

A

a sump or receiving tank
automatically lifted and discharged
storm drainage system or upon the ground outside the building it serves.