Water heaters used for domestic hot water can be used for space heating if
the water temp does not exceed 140
water heater installed in a crawl space must have
travel path no less than 5 feet of vertical distance
installed on at least 2 in thick corrosion resistance material adequate to support
attic, drop ceiling, or wood flooring water heater install must be…
installed with a corrosion resistant water tight pan below water heater
at least 3/4 in drain pipe similar to TP
On water heater install, the TP may discharge into drain pan if drain pipe is
equipped with 1 in drain, of suitable material for hot water, discharges through air gap into sump basin, service sink, o.r. or other approved discharge
Fuel fired water heater must be connected to
a flue or chimney
Flue or chimney of a water heater shall
at least size recommended by manufacturer
extend 2 ft above roof
properly flashed
not terminate within 6ft of door or window
Fuel fired water heater vent shall not
be connected to a flue serving a coal-burning apparatus
Fuel fired water heater shall not be placed in any
bathroom, toilet room, or a room used for sleeping unless it has a direct vent or through the wall vent system
Fuel-fired water heater shall not be placed in a closed room or closet unless
there is a louver door or ventilated to provide combustion air and circulation per NFGC
Gas fired direct vent requirements
vented per manufacturer
install to satisfy National Fuel Gas Code
50,000 BTU or less located at least 9in from any opening where flue gases may enter;
more than 50,000 at least 12 in`; bottom of vent terminal and air intake at least 12in above grade
in a location with a floor drain, TP relief valve may discharge into the floor if it
is piped to within 2in to the floor
without a floor drain, TP relief should be piped to
outside of the building with an ell turned down and to within 4 in of the surface of the ground
A trap or pipe shall not extend nearer to the floor than
12 inches except laundry trays or similar fixtures
Plastic water closet bowl shall have
3in water seal and 2 1/8 in waste opening passage
Frost-proof closet may may be installed only in a building
that has at least a 12in air break between it and any building used for habitation or occupancy