Section 5 - SOG - 3.20 Lightweight Construction Flashcards
SOG 3-20, Lightweight Construction,
Lightweight Construction, the term “lightweight construction” refers to
Structural systems and assemblies that are fabricated from components that have substantially less mass than traditional construction methods used for equivalent applications.
SOG 3-20, Lightweight Construction,
Unprotected lightweight construction systems that are involved in “or exposed to” a fire are susceptible to rapid failure in as little as
4 minutes
SOG 3-20, Lightweight Construction,
Examples of lightweight construction include:
Lightweight trusses and wood I-beams used in place of solid sawn lumber
SOG 3-20, Lightweight Construction,
When did engineered truss roofs become popular?
1970
SOG 3-20, Lightweight Construction,
When did engineered flooring systems first come to brampton?
1985
SOG 3-20, Lightweight Construction,
Upon discovery/confirmation of the involvement of lightweight construction if the fire, the IC should
Undertake a hazard risk assessment to ensure the safety of personnel
SOG 3-20, Lightweight Construction,
If a fire occurs in a structure that is known or suspected to incorporate lightweight construction this should be done
A hazard risk assessment
Notify personnel using emergency alerting
According to SOG 3-20, Lightweight Construction,
If while pre planing personnel find locations with unprotected lightweight floor systems this should be done?
Forward the location to communications so that a caution note may be added
SOG 3-20, Lightweight Construction,
When should the IC assume that a house has engineered roof trusses and or lightweight flooring?
If unable to determine the type of construction in a fire building andThe building was built post-1970 assume engineered roof trusses
If built post-1990 assume lightweight flooring
SOG 3-20, Lightweight Construction,
What shall occur when there are indications that unprotected lightweight construction is involved?
Extreme caution should be exercised when personnel are allowed to operate directly above or below areas that are supported by lightweight construction during a fire.
All personnel shall be immediately withdrawn from such areas if there are indications that unprotected lightweight consturction is involved in/exposed to the fire.
Consider using ladders to access upper floors
Consider using emergency alerting to notify personnel