Section 5 - SOG - 23.02 Fire Alarm Activation - No Access Flashcards

1
Q

According to SOG 23-01 Fire Alarm Activation - No Access,

Once the determination is made that access cannot be gained to the occupancy the Incident Commander (IC) shall; (confirm 3 things)

A
  • Confirm that a key-holder has been notified
  • Confirm the time of the notification
  • Confirm the estimated time of arrival for the key-holder
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

According to SOG 23-01 Fire Alarm Activation - No Access,

How long shall personnel wait with no access or fire conditions

A

Personnel shall wait thirty (30) minutes from the time the call was received for a key-holder. Apparatus are to be considered “available” while waiting. Wait times in excess of thirty (30) minutes will be at the discretion of the IC.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

According to SOG 23-01 Fire Alarm Activation - No Access,

Where no key-holder responds and access to the occupancy cannot be gained, personnel upon completion of their checks, shall

A

Complete a “Notice to Rectify” (NTR) that is to be left in a prominent place and leave the incident scene.

NTR’s issued for residential occupancies are for the homeowners information, they should be noted as such and will not require any further follow-up.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

According to SOG 23-01 Fire Alarm Activation - No Access,

If access cannot be made through normal means forcible entry should occur if:

A
  • There are visible signs of fire
  • There is a visible, steady, uninterrupted water flow
  • There is an obvious potential for an immediate danger to life or property (for example – a strong odor of a flammable gas)
  • There is a reasonable possibility that a medical emergency prompted the alarm activation
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

According to SOG 23-01 Fire Alarm Activation - No Access,

When notified that forcible entry has been used to gain access to the secured premise, Fire Control shall notify; (3)

A
  • Peel Regional Police
  • The Alarm Monitoring Company
  • The on-duty Platoon Chief
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

According to SOG 23-01, Fire Alarm Activation - No Access,

When personnel have attended a occupancy and no key-holder was met, a follow up visit should occur either by on-duty fire personnel or a Fire Prevention Officer within a reasonable time period in order to:

A
  • Update key-holder lists
  • Ensure the issued “Notice to Rectify” has been received and understood
  • Advise the owner/occupants or their representatives with regard to the correction of their system deficiencies
  • Make the owner/occupant aware of the key-box system
  • Tour the premise for familiarization purposes and answer any questions
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

According to SOG 23-01, Fire Alarm Activation - No Access,

Anytime forcible entry has been used to gain access to a premise the IC shall

A

Notify Fire Control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

According to SOG 23-01, Fire Alarm Activation - No Access,

While performing a 360 personnel shall

A

Preform a thorough check of the exterior, including the use of the thermal imagining camera, to ensure no fire hazard or medical problem exists and to determine the cause of the alarm.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly