S/G blowdown Flashcards
1
Q
Purpose?
A
- Aid in the protection of the S/Gs from corrosion during normal, ransient and inactive operational periods.
- 3 modes, SGBD/SGWLU/SGDRNDOWN
2
Q
R-19 A/B/C
High alarm does what
A
- Closes BD isolation valves
- closes BD sample isolation valves
- Closes BD Rate FCV’s
- Will close V1-31 if all 3 R-19’s alarm (does not auto re-open)
3
Q
FCV-4204 A/BC
Blowdown Rate FCV’s
A
- Control Blowdown rate between 0% and 100% open.
- Kept in manual position
4
Q
SGBD heat Xchangers
Max gpm?
Shell side?
Temps?
A
- 54gpm max
- CONDENSATE
- SGBD 510 to 146
- Condensate 102 to 131
5
Q
V1-31
Goes where?
Closes on what?
A
- Goes to Cir Water
- Closes when all R-19s alarm
- Must be manually re-opened
6
Q
SGBD Wet lay up pump trips?
A
- Flash tank lo-lo level 0%
- Low suction Pressure 1psi
- Auto close on FCV-4204s closure.
- auto close on blowdown isolation valve close while in blowdown mode
7
Q
Orifices’ in lines inside of C.V. do what?
A
- limit flow in case of downstream break
- are bypassed when plant is shutdown to allow greater flow rates.