S/G blowdown Flashcards

1
Q

Purpose?

A
  • Aid in the protection of the S/Gs from corrosion during normal, ransient and inactive operational periods.
  • 3 modes, SGBD/SGWLU/SGDRNDOWN
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

R-19 A/B/C

High alarm does what

A
  • Closes BD isolation valves
  • closes BD sample isolation valves
  • Closes BD Rate FCV’s
  • Will close V1-31 if all 3 R-19’s alarm (does not auto re-open)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

FCV-4204 A/BC

Blowdown Rate FCV’s

A
  • Control Blowdown rate between 0% and 100% open.

- Kept in manual position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

SGBD heat Xchangers
Max gpm?
Shell side?
Temps?

A
  • 54gpm max
  • CONDENSATE
  • SGBD 510 to 146
  • Condensate 102 to 131
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

V1-31
Goes where?
Closes on what?

A
  • Goes to Cir Water
  • Closes when all R-19s alarm
  • Must be manually re-opened
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

SGBD Wet lay up pump trips?

A
  • Flash tank lo-lo level 0%
  • Low suction Pressure 1psi
  • Auto close on FCV-4204s closure.
  • auto close on blowdown isolation valve close while in blowdown mode
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Orifices’ in lines inside of C.V. do what?

A
  • limit flow in case of downstream break

- are bypassed when plant is shutdown to allow greater flow rates.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly