NIS Flashcards
1
Q
Source Range Detectors
name, location, power supplies, type of counter
A
- N-31, N-32
- South/North (share well with IR) (18”-24” outside RV)
- IB-1/IB-2
- BF3 proportional counter
2
Q
Intermediate Range Detectors
names, locations, power supplies, type of counter
A
- N-35/N-36
- South/North (Share well with SR)(18”-24” outside RV)
- IB-1/IB-2
- Compensated Ion Chambers
3
Q
Power Range Detectors
names, locations, power supplies, type of counter
A
- N-41/N-42/N-43/N-44
- SE/NW/SW/NE (quadrants)
- IB-1/IB-2/IB-3/IB-4
- Uncompensated Ion Chambers
4
Q
R.G. 1.97 detectors
Names, locations, power supplies, type of counter
A
- N-51/N-52
- West/East
- IB-1/IB-8
- N51 alt power is DS Bus via kirk key
- Duel Fission Chambers (post accident monitoring)
5
Q
At Power Reactor Trips
A
- RCS Low flow
- RCP Break open
- 4KV Undervoltage
- PZR low pressure
- PZR high level
6
Q
Purpose of NIS (Nuclear Instrumentation system)
A
- To protect the reactor by monitoring the neutron flux and generating appropriate trips and alarms
- RG 1.97 monitor gross core power level (flux) for accident and post accident conditions