Reactor Trips Flashcards
1
Q
SR Hi Flux
A
- 10^5 cps
- 1/2 coincidence
2
Q
IR Hi Flux
A
- Amps for 25% power
- 1/2 coincidence
3
Q
PR Hi Flux low
A
- 24% power
- 2/4 coincidence
4
Q
PR Hi Flux Hi
A
- 108% power
- 2/4 coincidence
5
Q
Over Temp deltaT
A
- Variable
- 2/3
6
Q
Over Power deltaT
A
- Variable
- 2/3
7
Q
PZR Hi Pressure
A
- 2376psig
- 2/3
8
Q
PZR Lo Pressure
A
-1844psig
9
Q
PZR Hi level
A
- 91%
- 2/3
10
Q
4KV Busses Lo volt
A
- 3120V
- 2/3 busses
11
Q
One Loop Lo Flow
A
- 94.68%
- 2/3 loops
12
Q
Two Loop Lo Flow
10% Power
A
- 94.68%
- 2/3 loops
13
Q
S/G Lo-Lo lvl
A
- 16%
- 2/3
14
Q
SI
A
-CV 4psig/10psig (10psig Hi-HI)
-Low PZR Press (1715psig)
-High Differential steam line pressure
-High steam line flow
Manual
15
Q
Turbine Trip
A
- <800psig EH fluid
- stop valves close (2/2)