Review Flashcards
1
Q
Charging pumps provide what for RCP’s
A
- Seal water
- 8gpm, 5 down, 3 up
2
Q
RHR pump suction from?
A
- CV sump
- RWST
- Loop 2 Hot leg
3
Q
CV spray purpose?
A
- Lower CV pressure
- Lower CV temperature
- Control Iodine
4
Q
Pressure required to pump into RCS during a SI
A
- SI pump 1500psi
- Accumulator 630psi
- RHR pump 130psi
5
Q
RCS Loop3 lines
A
- Surge line (Hot)
- RHR/SI injection (cold)
- RVLIS (hot)
- Sampling (hot)
- SI Pumps (hot)
- RCDT (cold)
- Aux spray (cold)