What are the Rx Trip signals associated with NIs?
- SR High Flux
- IR High Flux
- PR High Flux, Low Setpoint
- PR High Flux, High Setpoint
- PR High Positive Rate
- Overtemp delta T
- Overpower delta T
What is the
Setpoint
Coincidence
Interlock associated with the SR High Flux Rx Trip?
90,000 cps and rising on 1/2
P-6
What is the Setpoint Coincidence Interlock associated with the IR High Flux Rx Trip?
22.5% (20%) RTP and rising on 1/2
P-10
What is the Setpoint Coincidence Interlock associated with the PR High Flux, Low Setpoint Rx Trip?
20% RTP and rising on 2/4
P-10
What is the Setpoint Coincidence Interlock associated with the PR High Flux, High Setpoint Rx Trip?
107% RTP and rising on 2/4
What is the Setpoint Coincidence Interlock associated with the PR High Positive Rate Rx Trip?
4.5% and rising in 2 secs on 2/4
What is the Setpoint Coincidence Interlock associated with the Overtemp delta T Rx Trip?
Variable setpoint as displayed on control board meter
2/4
What is the Setpoint Coincidence Interlock associated with the Overpower delta T Rx Trip?
Variable setpoint as displayed on control board meter
2/4
What are all the Rx Trip Signals?
SR High Flux IR High Flux PR High Flux, Low Setpoint PR High Flux, High Setpoint PR High Positive Rate Overtemp Delta T Overpower Delta T Pressurizer Pressure, High Pressurizer Pressure, Low Pressurizer Water Level High RCS Loss of Flow UV- RCP Busses Underfrequency - RCP Busses RCP Breaker Position SG Water Level, Low-Low SG Water Level Low w Feed Flow < Steam Flow Any SI Signal Turbine Trip Manual
What is the Setpoint Coincidence Interlock associated with the Pressurizer Pressure High Rx Trip?
2385 # and rising on 2/4
What is the Setpoint Coincidence Interlock associated with the Pressurizer Pressure Low Rx Trip?
1950# and lowering on 2/4
P-7
What is the Setpoint Coincidence Interlock associated with the Pressurizer Water Level High Rx Trip?
92% and rising on 2/3
P-7
What is the Setpoint Coincidence Interlock associated with the RCS Loss of Flow Rx Trip?
91% and lowering
> P-8 2/3 on 1/4 Loops
< P-8 > P-7 2/3 on 2/4 Loops
What is the Setpoint Coincidence Interlock associated with the UV- RCP Busses Rx Trip?
88 Volts indicated and lowering on 1/2 on 2/4 busses
P-7
What is the Setpoint Coincidence Interlock associated with the Underfrequency - RCP Busses Rx Trip?
58.2 Hz and lowering on 1/2 on 2/4 busses
P-7
What is the Setpoint Coincidence Interlock associated with the RCP Breaker Position Rx Trip?
Open auxiliary switch on 2/4
P-7
What is the Setpoint Coincidence Interlock associated with the SG Water Level Low-Low Rx Trip?
5% (22%) and lowering on 2/3 on 1/4 SGs
What is the Setpoint Coincidence Interlock associated with the SG Water Level Low w Feed Flow < Steam Flow Rx Trip?
15% (26%) and lowering on 1/2 on 1/4 SG
AND
0.71E6 (1.47E6) lb/hr on 1/2 on same SG
What is the Setpoint Coincidence Interlock associated with the SI Signal Rx Trip?
Either Train
What is the Setpoint Coincidence Interlock associated with the Turbine Trip Rx Trip?
Auto Stop Oil Pressure 800# and lowering on 2/3
OR
Stop Valves 1% and lowering on 4/4
C-8
What is the Setpoint Coincidence Interlock associated with the Manual Rx Trip?
Manual Switches 1/2
What are the SI Signals?
- Manual
- Ctmt Pressure High
- Pressurizer Pressure Low
- DP between Steam Lines (1 SG lower than 2 Others)
- SG Pressure Low
What is the Setpoint Coincidence Interlock associated with the Containment Pressure High SI Signal?
1.0 # and rising 2/3
What is the Setpoint Coincidence Interlock associated with the Pressurizer Pressure Low SI Signal?
1775 # and lowering 2/3
Manual Block with P-11
What is the Setpoint Coincidence Interlock associated with the DP between Steam Lines SI Signal?
100 psid 2/3 on any steam line
What is the Setpoint Coincidence Interlock associated with the SG Pressure Low SI Signal?
500 # and lowering 1/1 on 2 SGs
Manual Block with P-12
What are the signals for Containment Spray?
- Manual
2. Containment Pressure High-High
What is the Setpoint Coincidence Interlock associated with the Containment Pressure High High Containment Signal?
2.8 # and rising on 2/4
What is special about U1’s containment pressure high-high signal?
PPS will start a delay of 233 secs after reaching set point. white light on during delay period
What signals give a containment isolation phase A?
- Manual
2. SI
What signals give a containment isolation Phase B?
- Manual
2. Containment Pressure Hi-Hi
What signals can give you a Steam Line Isolation
- Manual
- Containment Pressure, High-High
- High Steam Flow with P-12
- SG Pressure Low
What is the Setpoint Coincidence Interlock associated with the Containment pressure high high SLI signal?
2.8 # and rising 2/4
What is the Setpoint Coincidence Interlock associated with the High Steam Flow with P-12 SLI Signal?
1.42E6 (1.6E6) pph at 0%; 1/2 on 2 SGs
Variable with power
NO BLOCK AVAILABLE
What is the Setpoint Coincidence Interlock associated with the SG Pressure Low SLI signal?
500# and lowering on 1/1 on 2 SGs
Manual Block w P-12
What signals will give a Turbine Trip and FWI?
- SG Water Level Hi-Hi
- SI
- Rx Trip w Low Tavg (FWI Only)
What is the Setpoint Coincidence Interlock associated with the SG Water Level Hi-Hi turbine trip / FWI signal?
67%NR and rising 2/3 on 1 SG
What is the Setpoint Coincidence Interlock associated with the Rx Trip w Low Tavg FWI signal?
Either Rx Trip Breaker open w Tavg < 554*F on 2/4 Loops
What is the Setpoint Coincidence Interlock associated with the 4 kV Bus Loss of Voltage MDAFP Autostart?
94 (93) V indicated and lowering
2/3 on T11A OR T11D
What is the Setpoint Coincidence Interlock associated with the 4 kV Bus Loss of Voltage MDAFP Valve Actuation?
94 (93) V indicated and lowering
2/3 on BOTH T-buses in SAME Train
What is the Setpoint Coincidence Interlock associated with the AMSAC MDAFP Autostart?
Feedwater Flow < 25% 3/4 feedwater flows
C-20
What is the Setpoint Coincidence Interlock associated with the SG Water Level Low-Low MDAFP Autostart?
5 (22)% and lowering 2/3 on 1 SG
What is the Setpoint Coincidence Interlock associated with the Loss of Both MFPs MDAFP Autostart?
FPT Stop valve closed limit switch 2/2 on each MFP
AUTO only
What is the Setpoint Coincidence Interlock associated with RCP Bus Undervoltage TDAFP Autostart?
88 V Indicated and lowering on 1/2 on 2 RCP busses
Time Delayed
What is the Setpoint Coincidence Interlock associated with SG Water Level Low-Low TDAFP Autostart?
5 (22)% and lowering on 2/3 on 2 SGs
What is the Setpoint Coincidence Interlock associated with AMSAC TDAFP Autostart?
Feedwater flow < 25% on 3/4 Feed flows
C-20
What is the Setpoint Coincidence Interlock associated with the CEQ Fan Start?
1.0 # and rising 2/3
Time Delayed
What are the Containment Isolation Purge and Exhaust Signals?
- High Containment Radioactivity Train A
2. High Containment Radioactivity Train B
A High Alarm on which rad monitors give a Train A containment isolation purge and exhaust signal?
VRS-1101 (2101)
Area Monitor and ERS-1300 (2300)
SPING Channels (1, 3, 5, 7, 9)
A High Alarm on which rad monitors give a Train B containment isolation purge and exhaust signal?
VRS-1201 (2201)
Area Monitor and ERS-1400 (2400)
SPING Channels (1, 3, 5, 7, 9)
What is the Setpoint Coincidence Interlock associated with the 4 kV Bus Loss of Voltage?
94 (93) V indicated and lowering
2/3 on any 4KV Safety bus
Time Delayed 2 secs
What is the Setpoint Coincidence Interlock associated with the 4 kV Bus Degraded Voltage?
113 V indicated and lowering
2/3 on T11A OR T11D
Time Delayed 2 mins (9 secs w SI or Lo-Lo SGWL)
What will cause a RWST Sequence? What is the associated Interlock?
2.5% indicated level and lowering 2/2
Either IMO-910/911 is full OPEN before VCT QMO-451/452 CLOSE