CCW Flashcards
What are the CCW Pump auto starts with the pump switch in auto?
- Load Shed
- SI
- Low discharge # @ 80#
What are the CCW Pump auto starts with the pump switch in neutral?
- Load Shed
- SI
What are the CCW Pump trips?
- Load shed
- Overload
- Overcurrent
What are the CCW Safeguards loads?
- RHR Hx
- RHR pp Seal Hx
- CTS pp Seal Hx
- SI pp LO Cooler & Seal Hx
- CCP LO cooler
What are the CCW Misc loads?
- SFP Hx - #1 load
- Letdown Hx
- Excess Letdown Hx
- RCP LO and Thermal Barrier Hx
- RCP Seal Water Hx
- CEQ Fan Motor Air Coolers
- WGC
- Reactor Vessel Support Coolers
- Cnt Penetration Coolers
- Sample HXs
- NBAE
- MS Penetration Coolers
- Recip CP
- Hydrogen Monitor
- PACHMAS
What isolates on a Phase “A” for CCW?
- SFP Hx Isolates
- Excess LD Hx Isolates
- Reactor Support Cooler Isolates
- NBAE Isolates
What isolates on a Phase “B” for CCW?
- RCP Cooling Isolates
(Thermal Barrier and Lube Oil coolers) - Requires Manual Trip of RCPs within 2 min **
What are the SI actions for CCW?
- CCW Hx Outlet Opens (also open on LOOP) **
- RHR Hx Outlet Opens to 3000 gpm
- ESW to CCW Hx throttles to 5500 gpm
- Letdown Hx Isolates
What are the power supplies for the CCW pumps?
- T11/21A West CCW Pump
- T11/21D East CCW Pump
What power supply does the Spare CCW pump use?
- Utilizes controls and power supply of pump being replaced
How tall is the baffle plate in the CCW Surge Tank and what is it for?
- Baffle plate is for train separation and its 48 in high = 3,300 gallons **
Does the surge tank have any auto makeup?
- No, Demin water makeup water valves (CRV-410/411) have no auto actions and they fail closed **
When will the CCW Surge tank vent valve (CRV-412) auto close?
- Vent valve (CRV-412) closes on CCW high rad signal
How do the demin water makeup water valves (CRV-410/411) fail?
- They fail closed on loss of air or DC power **
When does the CCW header low pressure alarm come in?
- Low pressure alarm is at 85 psig **