What are the condenser vacuum trips, and what does each trip?
21” - Main turbine trip and SCRAM if > 26% pow
16” - RFPT trip
12” - Combined stop and control valves close
9” - MSIVs close. Rx scram if mode switch in RUN
What does the steam chest feed?
MSR 2nd stage
What steam lines feed MSR ‘A’?
B and D
What steam lines feed MSR ‘B’?
A and C
How much steam can be bypassed?
30%
what’s the purpose of bleeder trip valves?
prevent reversal of extraction steam after turbine trip and prevent against water induction into the turbine
What’s the auto close of the bleeder trip valves?
Hi Hi level in associated drain tank OR
Turbine Trip
What are the loads off the equalizing header?
** CROSS **
C - Combined bypass stop and control valves
R - RFPT supply steam @ LOW POWER
O - Offgas preheater
S - SJAE
S - Seal steam generator @ LOW POWER
Where does MSR A/B get steam for its first stage reheater?
5th stage high pressure turbine
Where does the seal steam generator get its steam from? (low and high power)
Low power - Equalizing header
High power - Crossover steam (goes by many names)
What are the other ways of saying crossover steam?
cold reheat, high pressure turbine exhaust, 10 stage high pressure turbine, #5 HPFWH extraction steam
Name each feedwater heater’s steam sources
6 5 4 3 2 1 - Feed water heaters (steam load)
5 X 3 5 6 7 - Steam source