ADHR Flashcards

1
Q

What mode must you be in for spent fuel pool to Rx cooling?

A

Mode 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What cools the ADHR air conditioning?

A

PSW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where does the ADHR always inject to?

A

RHR C injection valve F042C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What mode of operation can ADHR be used?

A

4 and 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What temp and pressure can ADHR be used?

A

< 200 deg F and 0 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens if RHR C receives a start signal with ADHR in service?

A

Pump will start and trip on no suction path unless fuses are pulled or breaker is racked out

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What will trip the ADHR pump?

A

Low suction pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What cools ADHR heat exchangers?

A

PSW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What powers ADHR pumps?

A

14AE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Describe the alarms for ADHR?

A

No direct annunciator of pump trip!

but alarm on Hi temp or low flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How much flow is each pump providing?

A

1,800 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When will the low flow alarm come in?

A

1,000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the Process Rad Monitoring used for in ADHR?

A

Used to check for leakage into PSW system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Is the Process Rad Monitoring station for ADHR always in service?

A

No, it is only in service when ADHR is in service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly