Pre-flight checklists Flashcards
safety equipment before pax boarding
4.5.1.1 Aircraft Journey Logbook
> no FA pre-flight check.
4.5.1.2 Cabin Defect Logbook
Amount
It is there in the correct quantity
Secure
In designated stowage location
Sealed
N/A
Serviceable
Confirm previous entries have not been left in book and sufficient amount of pages remain to log new entries
Stow
Re-stow in designated stowage location
Log
If a new Cabin Defect Logbook is required, log it in the Cabin Defect Logbook
4.6.1 Galley
1
Galley lighting serviceable and circuit breakers not popped (if applicable)
2
Galley equipment stowed and secured. Ensure latches and clips are serviceable.
3
Commissary/catering boarded, stowed, and secured, as required.
4
Ensure galley secure for takeoff
4.6.2 Service Trolley
Amount
It is there in the correct quantity
Secure
In designated stowage location with break engaged, latches secured, and trolley is locked
Sealed
N/A
Serviceable
Can be removed from stowage and re-stowed with moderate effort, wheels roll and rotate easily. The braking system holds and releases
Stow
Re-stow and secure in designated stowage location
4.6.3 Lavatory
1
Ensure all required supplies are on board
2
Ensure toilet is functioning and whether servicing has been completed
3
Ensure that interior lighting is working, and call button is serviceable
4
Ensure cleanliness
5
Ensure placards affixed above the door handle to the lavatory on both the interior and exterior, display the symbol indicating that smoking is prohibited OR the words “NO smoking” and “Defense Fumer”
6
Ensure placards affixed above or on the opening of the waste disposal receptacle on the interior of the lavatory display the symbol indicating the cigarette disposal is prohibited OR the words “No cigarette disposal” and “Defense de jeter des cigarettes”
7
Ensure ashtray present on both the interior and exterior of the lavatory
4.6.4 Cabin
1
Ensure seats are not blocking and clear of the cabin emergency window exit
2
Complete a check of passenger call buttons to ensure serviceability (a spot check is sufficient)
3
Ensure aircraft has been groomed
4
Include a complete check of overhead bins to ensure nothing is left on from the day before or appeared during the night
5
Ensure an adequate supply of blankets
6
Ensure IWAC card is located in each pax seat and bulkhead
7
Ensure reading material (if applicable) is located in each pax seat and bulkhead
8
Ensure all crew personal belongings are stowed prior to passenger boarding
4.6.5 Seat Belt extensions
Amount
It is there in the correct quantity (5)
Secure
In designated stowage location
Sealed
N/A
Serviceable
Compatible with fixed passenger seat belts
Functioning buckles and not damaged
Stow
Re-stow in designated stowage location
4.6.6 Safety Features Card
Amount
It is there in the correct quantity
Secure
In each passenger seat pocket, bulkhead and extras in overhead bin
Sealed
N/A
Serviceable
Correct A/C type, legible and not damaged
Stow
Re-stow in designated stowage location
4.6.7 Passenger Seats and Restraints
Amount
It is there in the correct quantity
Secure
Secure to the floor
Sealed
N/A
Serviceable
Seats lock and table trays latched in upright position
Functioning buckles and not damaged
If unserviceable, notify PIC who will consult the MEL, have a placard that says “DO NOT OCCUPY”, fold the seat back fully and secure with seatbelt to prevent use, if necessary
4.6.8 Crew Member Seats and Restraints
Amount
It is there in the correct quantity
Secure
Secured to the bulkhead or the floor
Sealed
N/A
Serviceable
Harness attached, functioning buckles, not damaged
Fitted to size. (Sit and Fit). Seat self stows
ATR72 - 2nd FA jumpseat - slides and locks into stowage location
4.6.9 Overhead Bins
Amount
It is there in the correct quantity
Secure
Secured to aircraft
Sealed
N/A
Serviceable
Functioning handles, overhead bin door/panel is not damaged, and weight placarded
4.6.10 Supplemental Briefing Cards
Amount
Ensure two copies of each english and french
Secure
In designated stowage location
Sealed
N/A
Serviceable
All parts of the card are legible and not damaged
Stow
Re-stow in designated stowage location
4.6.11 Cabin Electronic Flight Bag (C-EFB)
1
Check for obvious damage
2
Battery level is a minimum of 90%
3
Devices and applications are all functioning
4
If the C-EFB is not serviceable, contact the FA management team immediately
4.7.1 Fire Extinguishers
Amount
It is there in the correct quantity
Secure
In the designated bracket
Sealed
Pin in place and tamper seal intact
Serviceable
Gauge indicates in the green zone
After cargo fire extinguisher, extension on the nozzle is attached
Stow
Re-stow in approved stowage location
Log
Log in cabin defect logbook
Replace
Maintenance will provide serviceable replacement
4.7.2 Lavatory Waste Bin Fire Extinguishers
> no FA pre-flight check.
4.7.3 Fire/Crash Axe
> no FA pre-flight check.
4.7.4 Fire Gloves
Amount
It is there in the right quantity (2 pairs)
Secure
In designated stowage location
Sealed
N/A
Serviceable
Gloves are in good condition and not damaged
Stow
Re-stow in approved stowage location
4.7.5 Crew Member Protective Breathing Equipment (PBE)
Amount
It is there in the correct quantity
Secure
In designated stowage location
Sealed
Tamper seal intact
Serviceable
Locate humidity indicator in the clear inspection window and ensure that it is visible and blue in colour
Stow
Re-stow in approved stowage location
Log
Log in cabin defect logbook
Replace
Maintenance will provide serviceable replacement
4.7.6 Approved Means of Flotation
Amount
Ensure there is and adult/child life vest for each FA
Ensure there is a adult/child life vest for each passenger seat (if applicable)
Ensure there are the correct number of infant life vests (if applicable)
Secure
In designated stowage location
Sealed
In a sealed pouch
Serviceable
N/A
Stow
Re-stow in approved stowage location
Log
Log in cabin defect logbook
Replace
Maintenance will provide serviceable replacement
Flotation Seat Cushions
> no FA pre-flight check.
4.7.7 Emergency Lights
1
Check floor level illuminating strips for signs of damage
2
Check all light fixtures, including emergency exit lights for signs of damage
3
Confirm emergency light activation switch is not damaged
4
Do not manually operate ELS to check light operation
4.7.8 DME Flashlights
Amount
It is there in the correct quantity
Secure
In designated bracket
Sealed
Tamper seal intact
Serviceable
Red indicator light blinks 3-10 seconds (20 seconds in extreme cold)
Stow
Re-stow in approved stowage location
Log
Log in cabin defect logbook
Replace
Maintenance will provide serviceable replacement
4.7.9 Emergency Locator Transmitter (ELT)
> no FA pre-flight check.
4.7.10 First Aid Book
Amount
It is there in the right quantity
Secure
In designated stowage location
Sealed
N/A
Serviceable
All parts of the book are legible and not damaged
Stow
Re-stow in designation stowage location
4.7.11 First Aid Kit
Amount
It is there in the right quantity
Secure
In designated stowage location
Sealed
Tamper seal intact
Serviceable
N/A
Stow
Re-stow in designated stowage location
Log
Log in cabin defect logbook
Replace
Maintenance will provide serviceable replacement
Fixed Oxygen System (opened with MRT)
Amount
It is there in the right quantity
Secure
In designated stowage location
Sealed
N/A
Serviceable
Not damaged
Stow
Re-stow in designated stowage location
Passenger Oxygen Masks
Amount
It is there in the right quantity
Secure
In designated stowage location
Sealed
In a sealed pouch
Serviceable
N/A
Stow
Re-stow in approved stowage location
Log
Log in cabin defect logbook
Replace
Maintenance will provide serviceable replacement
Portable Oxygen
Amount
It is there in the right quantity
Secure
In designated bracket
Sealed
Dust covers intact
Serviceable
Carry strap attached / 310L mask attached
PSI
Minimum 1500
Stow
Re-stow in approved stowage location
Log
Log in cabin defect logbook
Replace
Maintenance will provide serviceable replacement
Oxygen Restraint Device
Amount
It is there in the right quantity
Secure
In designated stowage location
Sealed
In storage pouch
Serviceable
Not damaged
Stow
Re-stow in designated stowage location, in storage pouch
4.7.13 Megaphone (ATR42 and ATR72)
Amount
It is there in the correct quantity
Secure
In designated stowage location
Sealed
N/A
Serviceable
Squeeze trigger and listen for amplified click
Stow
Re-stow in designated stowage location
4.7.14 Survival Equipment
> no FA pre-flight check.
4.7.15 Emergency Procedures Folder
Amount
It is there in the correct quantity
Secure
In designated stowage location
Sealed
N/A
Serviceable
Legible and correct folder for aircraft type
Stow
Re-stow in approved stowage location
Log
Notify flight attendant manager via email
Replace
Flight attendant manager will provide serviceable replacement
4.8.1 Public Address System and Interphone
1
Make TEST PA
2
Make a TEST call to the flight deck
Stow
Re-stow handset
4.9 Automated Announcement System
1
Play an announcement to ensure announcement system is working