Plumbing Fixture Flashcards
receptacle other than a trap in which water or wastes may be collected or retained for ultimate discharge into the plumbing system
FIXTURE
approved-type installed receptacles, devices or appliances we w pplied with water or receive liquid or liquid-borne wastes and discharge such wastes into the drainage system
PLUMBING FIXTURES
a minimum standard quantity of plumbing fixture
PLUMBING UNIT
an arbitrary quantity of the load-producing effects of water requirement equal to 28.3 liters per minute or 1 cu.ft/min
FIXTURE UNIT
plumbing fixtures for restricted use
PRIVATE OR PRIVATE USE
all bldgs or structures that are not defined as private or private use
PUBLIC OR PUBLIC USE.
adequately receive the discharge from indirect waste pipe constructed and located to be readily cleaned
RECEPTOR
any of two or more similar adjacent fixtures which discharge into a common horizontal soil or waste branch
BATTERY OF FIXTURES
installed to serve more than 1 appliance, fixture, bldg, or system
COMMON
All pipes from fixtures shall run _________ to the nearest wall or bldg. line
parallel and close
Floor mounted fixtures shall be secured on the drainage connection and floor with _________ of copper, brass, or other equally corrosion-resistant material
screws or expansion bolt
wall-hung fixtures shall be rigidly supported by ______
metal supporting members or chairs
water closet for obese
Bariatric water closet
Public water closets shall be the ______ type with ______ seats.
elongated bowl, open-front
max distance of WC or bidet from center to side wall
0.375 m
max distance of WC center to center
0.75 m
minimum dia. Of soil pipes serving WC
3”-4”
approximate dia. of closet flange
A. 178 mm
B. 38 mm
C. 6.4 mm
D. 51 mm
A.178 mm
width of closet flange
A. 178 mm
B. 38 mm
C. 6.4 mm
D. 51 mm
B. 38 mm
minimum thickness of caulked-on closet rings
A. 178 mm
B. 38 mm
C. 6.4 mm
D. 51 mm
C. 6.4 mm
minimum overall depth of caulked-on closet rings
A. 178 mm
B. 38 mm
C. 6.4 mm
D. 51 mm
D. 51 mm
number of bolts per closet ring or closet flange
A.2
B. 4
C. 6
D. 8
B.4
closet bends or stubs must be cut off ________ so as to present a smooth surface
square
gasket material shall be made of what material?
A. oakum
B. graphite-impregnated asbestos
C. oil tar pitch impregnated ground wood fibers
D. Asbestos fibers
B. graphite-impregnated asbestos
minimum distance of urinal from center to sidewall
0.30m
minimum distance of urinal center to center
0.60m
______ shall not be used for urinal tailpiece or trap
Brass or copper
________ shall protect water supply to urinal
VACUUM BREAKER
tanks flushing more than one urinal shall be _________ in operation
automatic
No __________ flushometer valve shall be used to flush more than one urinal
manually controlled
What is the material for restaurant Kitchen & other special use sinks?
Gauge 16 B&S (1.6mm) thk
Fixtures having concealed slip joint connections shall be provided with an access panel or utility at least _________ in its least dimension
0.3m
What is material is used for an exposed and readily accessible drawn brass tubing trap, excluding urine?
Gauge 17 B&S (1.1 mm) thk
what material is used for continuous waste and fixture tailpiece-seamless drawn brass?
Gauge 20 B&S (0.8 mm) thk
What is the thickness of copper pans or liners for shower subpans?
Gauge 24 B&S
What is the size of tailpiece for sinks?
38 mm OD
what is the size of tailpiece for dishwashers?
38 mm OD
What is the size of tailpiece for laundry tubs?
38mm OD
what is the size of tailpiece for bathtubs?
38 mm OD
What is the size of tailpiece for urinals?
38 mm OD
what is the size of tailpiece for lavatories?
32 mm OD
What is the size of tailpiece for drinking fountain?
32mm OD
Approved fitting for continuous waste
wye or other directional-type fitting