O2 Cylinders Flashcards
0
Q
What are the two main systems within the O2 system
A
- pilot system supplies pilot and flight engineers regulators
- copilot system supplies the copilot, navigator, radioman, and cargo compartment regulators
1
Q
Warning and safety precautions for O2 systems
A
- connect a/c to ground before operations
- disconnect external electrical power from a/c, place battery switch to off, and tag with danger tag.
- use only MIL-PRF-27210 type 1 aviators breathing O2 for filling and purging
- clean body, clothes, ppe from petroleum products(hair oil)
- do not allow O2 to mix with other vapors such as fuel fumes
- area is venilated
- keep O2 away from sources of heat, exhaust, flames, sparks, smoking
- air out clothing afterwards
2
Q
Cylinder systems
A
- pilot and flight engineer regulators use a 2 cylinder system
- all other regulators use a 5 cylinder system
3
Q
Cylinder installation
A
wrap threads of coupling with anti-seize tape, do not wrap on first 2 threads of fitting nearest opening.
tighten until bottoming then tighten additional 1/6 turn
4
Q
Replacement of drying agent cartridge is required after how many cylinders have been used IAW Oxygen Servicing Trailer Manual AFTO 35D3-6-48-1.
A
16
CGTO PG-85-00-310A P. 5-2
5
Q
HC-130 and HU-25 used what type pressure bottles
A
HC-130 low pressure 50-500 PSIG
HU-25 high pressure 50-1850 PSIG
M13520.1C 5-15