Full Face Quick Don Mask (HU-25) Flashcards
0
Q
Mask assemblies and operating procedures
A
- 72.5 psi is supplied
- can be donned single handedly in 5 seconds
- operating temp 4-140 degrees F
- operating pressure 60/25 psi
- max flow rate 120 L/min
- max operating altitude 40,000ft
- 5 sub assemblies
M13520.1C 5-18
1
Q
What minor repairs are authorized
A
The ICS connection plug only
CGTO PG-85-00-310A P. 5-8
2
Q
Preventative maintenance is limited to what
A
Replacement of the face plate, protective strip, cleaning, and disinfecting the subassemblies
CGTO PG-85-00-310A P. 5-8
3
Q
The mask is used for both respiratory and eye protection. It is supplied with oxygen at a rated pressure of ___ psig.
A
72.5 psig
M13520.1C 5-18
4
Q
How can the mask be donned
A
Singled handed in less than 5 seconds
M13520.1C 5-18
5
Q
What is the anti-mist condenser made of
A
Aluminum alloy
M13520.1C 5-20
6
Q
What does the test and emergency knob on the regulator subassembly do
A
- functional test of the regulator when depressed
- delivery of positive safety pressure at any altitude when turned clockwise
M13520.1C 5-21