CG-P1B-GX120 SALVAGE PUMP Flashcards
What type of Carburetor is installed on the pump?
Two-piece Flo-jet(small)
What is the minimum octane that can be run in the pump?
85
unleaded
What is the spark plug gap on the pump?
.030in
MPC 256038.1 P. 9, 31
What types of oil are used on the pump?
SAE 30 for 50 degrees and up
5W30 for 30 degrees and down
10W30 for -5 degrees and up
MPC 256038.1 p 8
What spark plug is used on the pump?
NGK BPR6ES or DENSO W20EPR-U(commercial purchase)
MPC 256038.1 p 9
How long is the type one nylon cord that attaches to the 6volt explosion proof flashlight to the instruction card?
36inches bowline followed by a stopper knot on both ends.
D cell batteries
MPC 256038.1 P. 14
How is the extra suction hose gasket secured to the underside of the lid?
place the spare gasket into a 4x6in interlocking bag and close. tape the bag inside of the lid using a strip of duct tape. stencil “extra suction hose gasket” in 1”letters with black enamel tape.
MPC 256038.1 p. 14
What are the languages on the instruction card?
english, french, spanish, vietnamese
What is the size of the letters of the unit address on the pump container and “no smoking, gas in can”?
1” black enamel letters
two opposing sides of lid for no smoking
What size breakaway wire is used
0.020 in copper
MPC 256038.1 P. 18
How long will the pump take to prime at a ten foot lift?
no more than 30 seconds
MPC 256038.1 p 25
What is the most likely cause of failure?
moisture in the gas can
What is the maximum amount of pulls allowed to start the pump?
6 pulls
MPC 256038.1 p 26
What color is the crankcase oil filler cap
gray on one side black on the other
MPC 256038.1 p. 8
What size socket goes on the 3 bolts of the crankcase housing pull starter housing to flywheel cover
10mm
MPC 256038.1 p 9
What position does the recoil pull starter get stationed after reinstalling the quick release L-bolts
clockwise to the 1 o clock position
MPC 256038.1 P. 9
How far from the frame will the fuel can retention hook be after bending with pliers
1/8in
MPC 256038.1 P. 10
Fuel line retention rubber band
larks head rubber band to pump frame adjacent to fuel connector on fuel can. loop end of rubber band over fuel line between the fuel filter and the carburetor
MPC 256038.1 p 11
Oil alert sensor cutoff switch and unit
switch bracket bolted directly to flywheel shroud
unit in engine case has one yellow wire extending from rubber core. cut yellow wire flush with the sending unit
MPC 256038.1 p 12
Starter Rope
fold starter rope twice attach with larks head knot to pump frame handle at priming pump
MPC 256038.1 P. 14
Cold Start
- ensure the fuel valve lever in moved to the right “on” position
- ensure choke lever is moved to the left to “closed” position
- ensure throttle switch is moved to left from “slow” position to the “fast” position
- turn engine switch “on”
MPC 256038.1 P. 24/25
For the test, pump should be __ to __ ft above the water.
10-15 ft
M10470.10E p. 2-27 Note
What is one probability for the engine to fail to start?
Condensation (moisture) in the container
MPC 256038.1 P. 26
What are effective ways to rid the pump container of moisture?
Completely drying kit components and by using proper packaging methods. vacuum cleaner discharge air, directed into the hoses and pump housing.
MPC 256038.1 P. 26
What size is the armature gap?
.010 in using a feeler gauge
MPC 256038.1 P. 35
What type grommet is used for the instruction placard
00 plain grommet
MPC 256038.1 P. 14