Where a compartment containing an OF boiler or circulator the air vents must not communicate with:

a) a private garage
b) a bedroom
c) a bed-sitting room where the input rating >14kW gross
d) bath and/or shower room
e) all of the above

A

e) all of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If an OF appliance in a bedroom located compartment what additional steps should be taken?
4 of them

A

1) Self closing door
2) Draught proof door
3) Door kept shut at all times – unless access to controls required
4) Compartment must not be used for storage etc

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If a boiler or circulator is installed in an under stairs cupboard what two additional factors should be considered

A

1) Really should be RS
2) All internal surfaces 30 mins fire resistance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is a circulator?

A

An appliance to provide hot water to a storage vessel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Gas fire hearth requirements – what are the minimum dimensions

M16/p20

A

A = 300mm
B = 150mm

At least 50mm above floor with a non-combust surface >12mm thick