Module 14 Flues Flashcards
Name the four components in the flue pipe installation:
1 – Flue terminal
2 – Storm collar
3 – Weather proof plate
4 – Fire stop plate clamp
When installing a new appliance which is preferred:
a) Flueless
b) Open Flued
c) Room Sealed
c) Room Sealed
When installing a balanced flue R/S through a cavity with insulation how much of a gap must be left between the flue and the insulation?
a) 10mm
b) 25mm
c) 50mm
d) 75mm
b) 25mm
When would you use a heat shield on a flue terminal?
Within 1m of a plastic gutter or 0.5m of painted eaves/gutter
When would you install a flue terminal guard?
When terminal is less than 2m above any area of access e.g. flat roof, path etc.
When a flue pipe runs through an insulated roof space it should be:
a) uninsulated, unsupported
b) insulated, unsupported
c) uninsulated, supported
d) insulated, supported
d) insulated, supported
Flexible flues can be installed in lengths of:
a) 1m
b) 3m
c) 10m
d) Continuous length
d) Continuous length
A flexible flue liner should be sealed at:
a) Top only
b) Bottom only
c) Top and Bottom
d) Continuous
c) Top and Bottom
What is the common name for a vertical balanced flue?
Vertex Flue System
A Vertex Flue System is:
a) horizontal balanced flue
b) vertical fan flue
c) horizontal fan flue
d) vertical balanced flue
d) vertical balanced flue
A Vertex type flue will have a draught diverter in:
a) Same compartment as the boiler
b) Ventilated roof space
c) Either of the above
d) Ventilated roof space