LOT 201.21 Containment Isolation Flashcards
- LOT 201.21 Containment Isolation*
- *
What will cause a Phase B CIS?
Containment Pressure - High 3 (9.5 psig) [2/4]
Manual [2/2 on 1/2] (CP002/CP005)
Reset located on CP002.
Note:
- Initiates Containment Spray
- Manual initiation will only open valves (Must manually start pump)
- Isolates CCW to RCPs (6 Valves)
- LOT 201.21 Containment Isolation*
- *
An ESF actuation is designed to protect the general public from the release of FPP due to what types of accidents?
LOCA
Fuel Handling Accident
- LOT 201.21 Containment Isolation*
- *
Does charging isolate on a phase A containment isolation?
Yes
Seals do not isolate.
What are the ≤ 1 hr actions for LCO 3.6.1.1 Containment Integrity?
LCO 3.6.1.1 Containment Integrity
Action a.
Loss of Containment Integrity
Restore Integrity [1 hr]
OR
Be in MODE 3 [6 hrs]
AND
Be in MODE 5 [following 30 hrs]
- LOT 201.21 Containment Isolation*
- *
What will cause a Phase A CIS?
SI
P-11 False:
PZR Pressure - Low (1857 psig) [2/4]
Steam Pressure - Low (735 psig) [2/3 on 1/4]
No Permissives:
Containment Pressure - High (3.0 psig) [2/3]
Manual [1/2] (CP001/CP005)
Manually [1/2] (CP002/CP005)
P-11 False: PZR Pressure ≥ 1985 psig [1/3]
Reset located on CP002.
- Note:*
- Will effect systems not safety related. (i.e IA to RCB)*
- LOT 201.21 Containment Isolation*
- *
What temperature and/or pressure would make a system a high energy system?
> 200 ˚F
> 225 psig
- LOT 201.21 Containment Isolation*
- *
What will cause a SL Isolation Signal?
- ≥ P-11:*
- *Steam Pressure - Low (735 psig) [2/3 on 1/4]**
- < P-11:*
- *Steam Pressure Rate - High (100 psig w/ 50 sec TC) [2/3 on 1/4]**
- No Permissive:*
- *Containment Pressure - High 2 (3.0 psig) [2/3]**
- *Manual [1/2] (CP005/CP006)**
P-11: PZR Pressure < 1985 psig [2/3]
Resets located on CP005/CP006.
- Note:*
- Isolates MSIVs and MSIV bypass valves.*
When is LCO 3.6.1.1 Containment Integrity applicable?
MODES 1 - 4
- LOT 201.21 Containment Isolation*
- *
What causes a containment ventilation isolation signal?
- No Permissives:*
- *SI**
- *Radiation - High (RT8012/RT8013) [1/2]**
- Manual:*
- *Containment Phase A [1/2]**
- (CP002/CP005)*
- *Containment Phase B [2/2 on 1/2]**
- (CP002/CP005)*
Reset located on CP022.
- Note:*
- Isolates Containment Normal and Supplemental Purge Systems and Containment Airborne Activity Monitor (RT-8011)*
- LOT 201.21 Containment Isolation*
- *
What causes a Feedwater Isolation Signal?
- P-4 True:*
- *Tave - Low (574 ˚F) [2/4]**
- No Permissives:*
- *SI**
- *P-14**
- S/G Level - High (87.5%) [2/4 on 1/4]*
P-4 True: Rx Trip [2/2] AND Bypass Bkrs [2/2] open
- Note:*
- Closes FWIVs, bypasses, FRVs, Low FRVs, trips MFP turbines, and trips turbine.*
- LOT 201.21 Containment Isolation*
- *
What types of lines require containment isolation?
Lines that form part of RCPB
Lines that connect to containment atmosphere
Lines that are part of a closed system