LOT 201.21 Containment Isolation Flashcards

1
Q
  • LOT 201.21 Containment Isolation*
    • *

What will cause a Phase B CIS?

A

Containment Pressure - High 3 (9.5 psig) [2/4]

Manual [2/2 on 1/2] (CP002/CP005)

Reset located on CP002.

Note:

  • Initiates Containment Spray
    • ​Manual initiation will only open valves (Must manually start pump)
  • Isolates CCW to RCPs (6 Valves)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • LOT 201.21 Containment Isolation*
    • *

An ESF actuation is designed to protect the general public from the release of FPP due to what types of accidents?

A

LOCA

Fuel Handling Accident

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • LOT 201.21 Containment Isolation*
    • *

Does charging isolate on a phase A containment isolation?

A

Yes

Seals do not isolate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the ≤ 1 hr actions for LCO 3.6.1.1 Containment Integrity?

A

LCO 3.6.1.1 Containment Integrity
Action a.
Loss of Containment Integrity

Restore Integrity [1 hr]

OR

Be in MODE 3 [6 hrs]
AND
Be in MODE 5 [following 30 hrs]

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • LOT 201.21 Containment Isolation*
    • *

What will cause a Phase A CIS?

A

SI
P-11 False:
PZR Pressure - Low (1857 psig) [2/4]
Steam Pressure - Low (735 psig) [2/3 on 1/4]

No Permissives:
Containment Pressure - High (3.0 psig) [2/3]
Manual [1/2] (CP001/CP005)

Manually [1/2] (CP002/CP005)

P-11 False: PZR Pressure ≥ 1985 psig [1/3]

Reset located on CP002.

  • Note:*
  • Will effect systems not safety related. (i.e IA to RCB)*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • LOT 201.21 Containment Isolation*
    • *

What temperature and/or pressure would make a system a high energy system?

A

> 200 ˚F

> 225 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • LOT 201.21 Containment Isolation*
    • *

What will cause a SL Isolation Signal?

A
  • ≥ P-11:*
  • *Steam Pressure - Low (735 psig) [2/3 on 1/4]**
  • < P-11:*
  • *Steam Pressure Rate - High (100 psig w/ 50 sec TC) [2/3 on 1/4]**
  • No Permissive:*
  • *Containment Pressure - High 2 (3.0 psig) [2/3]**
  • *Manual [1/2] (CP005/CP006)**

P-11: PZR Pressure < 1985 psig [2/3]

Resets located on CP005/CP006.

  • Note:*
  • Isolates MSIVs and MSIV bypass valves.*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When is LCO 3.6.1.1 Containment Integrity applicable?

A

MODES 1 - 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  • LOT 201.21 Containment Isolation*
    • *

What causes a containment ventilation isolation signal?

A
  • No Permissives:*
  • *SI**
  • *Radiation - High (RT8012/RT8013) [1/2]**
  • Manual:*
  • *Containment Phase A [1/2]**
  • (CP002/CP005)*
  • *Containment Phase B [2/2 on 1/2]**
  • (CP002/CP005)*

Reset located on CP022.

  • Note:*
  • Isolates Containment Normal and Supplemental Purge Systems and Containment Airborne Activity Monitor (RT-8011)*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  • LOT 201.21 Containment Isolation*
    • *

What causes a Feedwater Isolation Signal?

A
  • P-4 True:*
  • *Tave - Low (574 ˚F) [2/4]**
  • No Permissives:*
  • *SI**
  • *P-14**
  • S/G Level - High (87.5%) [2/4 on 1/4]*

P-4 True: Rx Trip [2/2] AND Bypass Bkrs [2/2] open

  • Note:*
  • Closes FWIVs, bypasses, FRVs, Low FRVs, trips MFP turbines, and trips turbine.*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
  • LOT 201.21 Containment Isolation*
    • *

What types of lines require containment isolation?

A

Lines that form part of RCPB

Lines that connect to containment atmosphere

Lines that are part of a closed system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly