Loss Of 1500vDC Power Flashcards

1
Q

What 1500v DC equipment if develops short circuit, can cause overhead power supply to shut down to avoid damage to substation?

A

Pantographs

Motor Alternators

Air Compressors

Traction equipment

Associated circuits

EXAM - trains cause faults not substations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When there is loss of overhead power how many times will overhead system attempt to reset itself?

A

Twice

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What happens to Comeng doors if there is no overhead power?

A

Doors are released

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What will Metrol do if unable to restore overhead power?

A

Make radio group call requesting all drivers to lower pantographs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When overhead power has been restored what will Metrol do?

A

Depart one train at a time in one minute intervals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What does the driver have to do once instructed to depart?

A

Raise all pantographs

Start all MAs

Run in SERIES until location advised by TC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When no comms are available and train fails what must a driver not do?

A

Don’t assume loss of overhead power has occurred.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

With no comms and train fails what should a driver do?

A
  1. Trip, Switches, Gauges, Cocks
  2. Check 110vDC power - bell, low pressure flag, EP brake operational
  3. Check AC power available - non- emergency saloon lights available, van area cab light, headlights
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

With no comms, once train is started how long do you have to wait before applying power?

Then what do you do?

A

30 seconds for an up train

60 seconds for a down train

Run in SERIES until next station

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How long will emergency lights operate with no overhead power?

A

2 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How will Driver know the emergency lighting needs to be reset?

A

Battery charger light will flash

Turn marker lights from auto to any position and back again.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How long will PA system remain operational?

A

2 hours.

Will be reset with lighting.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are the two components of the LSM that monitor train status?

A

Time Delay Relay

Speed Threshold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the LSM Speed threshold?

A

8kmh

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does LSM do with BVICS open in leading car if speed is over 8kmh and overhead power is lost?

A

EP CB trips - running on air brake

Shuts down local MA

Lowers all trailing pantographs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What does the 110vDC output have to drop to for the LSM to take action?

A

95vDC for 2 continuous seconds

17
Q

What does LSM do with ALL BVICS closed speed zero and timers within 4 minutes?

??????????

A

EP CB Trips - running on air

Shuts down what was lead MA

Lowers all trailing Pantographs

18
Q

What does LSM do with all BVICS closed, speed zero, timers zero?

A

MA Contactors set to OFF

All pantographs will lower

PA and emergency lighting will be available.

19
Q

How long will VICERS take to operate when pantos are dropped?

A

5 minutes

VAV will open after 5 minutes

20
Q

If power is restored and Metrol have established the problem isn’t weak substation output, the cause is a train with defective 1500vDC equipment.

What will TC do?

A

Work with trains one by one requesting each driver to raise all Panto’s and start all MA’s.

When overhead power is lost, the defective train has been identified

21
Q

If MAs Overspeed can they be reset by traction overload reset button?

A

No

22
Q

What can weak substation output cause?

A

Reduced traction effort

Reduced Rheo performance

Loss of one or more AC

Loss of one or more MA