Door Defects & Lighting Defects Flashcards

1
Q

What does the Door Loop Isolation do?

A

Allows train to get traction power while it has FDCL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If a door is defective what will it do?

A

Tone will sound for 60 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What can cause FDCL? (8)

A

Control CB tripped

Aux. CB tripped

BVICS open in last car

Marker lights in last car in wrong position

Saloon doors failing to close

PLC CB in any trailing car isolated

Open circuit in train cable

Coupler sensor defective

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If only one door defective what is likely cause?

A

Mechanical

Close, temp locking device, sticker, TMM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When doors on one side of a car are defective what is the likely cause?

A

Electrical or pneumatic

Check electrics in cabinet above door 3
Check ICs under train

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When all doors on a car are defective what is the likely cause?

A

Electrical or pneumatic

Same as previous

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When all doors on the train are defective what is the likely cause?

A

Electrical

Check Aux. CB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What else does Aux. CB control?

A

Bells
Aux. start
Doors open & close

Saloon lights
Couple and Uncouple Button
AC no. 1 end
Self- centering device on coupler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How do you apply temporary door locking device to a Comeng?

A

Open pelmet above defective door

Serated side on inside

Cable around door mechanism

Pull tight

Attempt to force door

Close pelmet

Door stickers

TMM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is procedure for FDCL while moving?

A

Slow down

PA

TC

Stop at next station regardless

Attempt to close doors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is procedure for FDCL while at platform?

A

TC, PA, full cab unattended

TMM, radio, stickers

Close doors and walk first unit listening … repeat for second unit.

Isolate defective door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How is saloon lighting powered?

A

By MAs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If you detect defective saloon lights what is the first thing you should check?

A

MA fault light

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If the whole train has saloon lights out what do you do?

A

Observe at least one Panto up

Check 110VDC supply

Trip and reset Aux. CB

Press saloon light ON button x 3 then press for 5 seconds

If that doesn’t work go to another cab and press x 3 and hold for 5 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If half saloon lights are inoperative in one car what is likely cause?

What do you do?

A

Contactors not set and not activating circuits

Press Saloon light ON button x 3 then press and hold for 5 seconds

If that doesn’t work check saloon lighting MCB above door 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If lighting is extinguished in a regular sequence what does that mean?

A

Lighting CB has tripped - above door 3

Or isolation switch is in off position - above door 3

17
Q

When individual lights are extinguished in no discernible pattern what does it mean?

A

Inoperative tubes

Book TMM

18
Q

What happens if all lights are defective in one or more cars and emergency lights are inoperative?

A

Train cannot operate:
In hours of darkness
In the MURL
In West Richmond Tunnel

19
Q

How long will emergency lighting operate?

How do you reset it?

A

2 hours

Move marker lights to any position and back to Auto

20
Q

If there is half saloon lighting in one UNIT what would be the cause?

A

One MA inoperative