Liquid Rad Waste (WDS) Flashcards
What will auto close the Unit Release Valve (RRV-286/287)?
NO CW Pumps running in associated unit
When do the aux building floor drains drain to?
- 609’ and above drains go to DWHUT.
- 587’ drains go to Dirty Sump Tank.
- 573’ drains go to Aux Sump.
What is the Interlock for CWHUT and DWHUT inlet valves? (RRV-255/256)
Interlocked so that both cannot be closed at the same time (prevents backing up of drains)
Which ONE of the following describes three sources of liquid waste to the Reactor Coolant Drain Tank?
A. Excess Letdown Heat Exchanger , Lower Containment Sump, Charging Line Suction Relief
B. RCS Loop Drains, Reactor Vessel Flange Leak Off, SI Accumulator Tank Drains
C. RCS Loop Drains, Pressurizer Relief Tank, Reactor Cavity Sump
D. RCP Thermal Barrier Relief, Excess Letdown/Seal Return Relief, Reactor Vessel Flange Leak Off
- B. RCS Loop Drains, Reactor Vessel Flange Leak Off, SI Accumulator Tank Drains
What Drain sources tap into RCDT Outlet piping?
- RCP #3 Seal
- PRT
What drains into the CWHUT?
Hard Piped equipment drains from the 609’ and above
What 3 sumps are pumped out of containment? Where do they go?
All pump to DWHUT/CWHUT
- Lower Ctmnt Sump
- Reactor Cavity Sump
- Pipe Tunnel Sump
Where do the Clean/Dirty Sump tanks overflow?
Aux Sump
What drains into the Clean Sump Tank?
Hard Piped drains on the 587’
Where do drains on the 573’ Elevation go?
Aux Sump
Where does the RCDT receive drains from?
- Accumulator Drains
- XS LD Hx Drains
- Regen Hx Drains
- RCS Loop Drains
- RCP #2 Seal Leak off
- Rx Vessel Flange Leakoff
- Refueling Cavity