What are the MDAFP Auto Starts?
- Both MFP Trips (in Auto)
- AMSAC (C-20)
- Load Shed
- Low-Low SG Lvl (2/3) on 1 SG
- SI
What are the TDAFP Auto Starts?
- Undervolt on the RCP Bus (2/4 RCP busses at 88v)
- SG low low lvl (2/3) on 2 SGs
- AMSAC (C-20)
What are the suction sources of the AFW pumps?
- Own CST
- Other Unit CST
- ESW
What happens on an AFW Flow Conservation signal?
- SG Blowdown Isolations Close
- AFW Pump Test Valves Close
- MDAFP FMOs OPEN (regardless of position)
- seals in for 45 seconds to ensure the FMOs OPEN
What causes an AFW Flow Conservation Signal?
Anything that starts MDAFW pump auto start
What does the AFW flow retention signal do?
Protect against run-out after steam/feed break by limiting flow from the AFW pumps that may be supplying the faulted SG
What happens on a AFW flow retention?
Pump discharge valves throttles back
- MDAFP 575 gpm
- TDAFP 955 (975) gpm
What causes an AFW Flow Retention Signal?
High AFW pump discharge flow
Which AFW signal overrides the other? (Retention or Conservation)
Flow Retention overrides Flow Conservation
What is the TDAFP Turbine oil Cooler and Governor Oil Cooler cooled by?
TDAFP discharge
If you put the TDAFP ELO switch in Manual what will the valve do?
Stay open
How do the TDAFP ELO fail on loss of air and ctrl power?
Open
Where does the back up water supply to the suction of the MDAFPs come from?
East ESW Header
Where does the back up water supply to the suction of the TDADPs come from?
West ESW Header
What will cause an AMSAC Signal?
FW Flow less than 25% (3/4 feed flows)