Liquid Chromatography Flashcards

1
Q

Which of the following is the disadvantage of reciprocating pump used in liquid chromatography?
a) Produces pulsed flow
b) Corrosive components
c) Does not have small hold-up value
d) Does not have moderate flow rate

A

a) Produces pulsed flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which of the following is not a disadvantage of Pneumatic pumps used in liquid chromatography?
a) Pulsed output
b) Dependent on solvent viscosity
c) Dependent on back pressure
d) Inconvenient for solvent gradient elution

A

a) Pulsed output

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which of the following is not a desired characteristic of pulse dampers or flow smootheners used in liquid chromatography?
a) Easy mobile phase change over
b) Constant flow must be maintained
c) Should be effective at low system pressure
d) Maximal dead volume

A

d) Maximal dead volume

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which of the following will improve the efficiency of the separation process in liquid chromatography?
a) Increase in sample size, increase in column diameter
b) Reduction in sample size, increase in column diameter
c) Increase in sample size, reduction in column diameter
d) Reduction in sample size, reduction in column diameter

A

d) Reduction in sample size, reduction in column diameter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which of the following are the practical problems that arise due to the decrease in column diameter?
a) Requirement of large particle size and high pressure drop
b) Requirement of large particle size and low pressure drop
c) Requirement of small particle size and high pressure drop
d) Requirement of small particle size and low pressure drop

A

c) Requirement of small particle size and high pressure drop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which of the following is not true about the guard column used in liquid chromatography?
a) It filters particles that clog the separation column
b) It extends the lifetime of separation column
c) It allows particles that cause precipitation upon contact with stationary or mobile phase
d) The size of packing varies with the type of protection needed

A

c) It allows particles that cause precipitation upon contact with stationary or mobile phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which of the following columns are not used in liquid or high-performance liquid chromatography?
a) Analytical column
b) Separation column
c) Guard column
d) Capillary column

A

d) Capillary column

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which of the following is not a Column-type Liquid chromatography?
a) Gel permeation
b) Ion exchange
c) Liquid-solid
d) Paper

A

d) Paper

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which of the following is not true about the radial compression column when compared to standard separation column?
a) Internal diameter decreases
b) Overall operating pressure decreases
c) Analysis time decreases
d) Solvent flow increases

A

a) Internal diameter decreases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which of the following is not true about narrow bore column when compared to standard columns?
a) Internal diameter decreases
b) Volumetric flow decreases
c) Solvent cost is saved
d) Detector response time increases

A

d) Detector response time increases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which of the following types of liquid chromatography uses immobilized biochemical as a stationary phase?
a) Ion exchange chromatography
b) Exclusion chromatography
c) Affinity chromatography
d) Gel permeation chromatography

A

c) Affinity chromatography

How well did you know this?
1
Not at all
2
3
4
5
Perfectly