Lesson 17: Blowdown Recovery System Flashcards

1
Q
  1. What is the purpose of the Blow down Recovery System?
A

Boiler water is sent through the Demineralizer, which removes silica so that it can be reused as clean condensate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  1. If the Blow down Recovery System is not available what can we use to control Silica in Boiler water?
A

Big Blowdown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  1. What does the Blow down Recovery system heat exchanger use to cool the recovered water?
A

The primary heat exchanger uses condensate.

The secondary heat exchanger uses ACW.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  1. On the Small blow down what is the normal setting?
A

1/10th of a round

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  1. Where does the Blow down Recovery storage tank pump the recovered water to when the tank becomes full?
A

Recovered water is pumped through the demineralizer then out to the condensate tanks.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  1. At what temperature does the Recovery block valve trip closed?
A

185 C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  1. What is the reason for tripping the recovery block valve?
A

To protect the heat exchanger and storage tanks.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly