Integrated Safeguards Flashcards
State Containment DBA
Double ended break of RCP piping
One CBS train Fails to start
One EDG fails to start
52# max calculated containment pressure
State other action of P-11
Blocking P-11 will block MS low steam line pressure (585#) SI
AND
Enables Steam Line Pressure rate hi MSI (100# for 50 sec)
State what a “Dual Function” valve means
Dual Function valves are valves that comply with more than 1 T.S. and compliance with one will mean non-compliance with the other T.S.
See OPMM for guidance
List the Five Major categories of ESF
Containment systems ECCS Habitability systems Fission product removal and control systems EFW
List the 4 Subsystems that are part of the Containment system
Primary containment and enclosure structures
Containment heat removal systems
Containment isolation systems
Combustible gas control systems
State plant response to SI
RX trip ECCS actuation EFW CBA goes to filter recir mode EDG start Phase A isolation CVI FWI Turbine trip MFP trip
State plant response to Phase A
Isolation of non containment CVI Electrical penetration sump pump trips Initiates CC to RHR HX EAH to emergency mode starts EAH fans Isolates IA to Containment
State plant response to Phase B
Isolates CC to containment (not thermal barrier)
Opens CC to CBS HX
Trips CRDM cooling fans
Starts CAH-FN-3A/B in recirculation mode
State plant response to CVI
Trips Make up fans (27 A/B) Closes Make up fans dampers (53 A/B) Opens DP-27A/B which starts FN-16A/B Exhaust FN-15 Trips Exhaust dampers (28/1058) close