CAH Flashcards
State CAH response of loss of PCCW
CAH cooling fans trip
State how CAH fans respond on LOP
CAH fans restart at step 3 of EPS assuming no SI or P signal
- fans will trip if CC doesn’t start on next step of EPS
State CRDM fan response to P signal
Fans will trip
State start permissive for CAP-FN-35
RM-6535 must not be in alert in order to start
State CVI actuation signals
SI Manual Phase A Manual Phase B Hi rad signals on COP monitors Hi rad signal on refueling bridge monitors
State what CVI will not affect
Refueling Purge Exhaust fan (CAP-FN-35)
RCA Supply Fan 179
CAP Fan 10
State how CVI will affect CAP
Closes CAP valves CAP-V-1, 2, 3, & 4 and prevents opening
(1 & 4 A train, 2 & 3 B train)
Trips Pre-entry Purge Supply fan (CAP-FN- 9) and Refueling Purge Supply fan (CAP-FN-34).
Prevents fan start
A train only
No input from B train CVI
State how CVI will affect COP
Trips COP Supply fan FN-73 and prevents start
A train only
No input from B train CVI
Closes COP V-1, 2, 3, & 4 and prevents opening
(V1 & 4 A train, V2 & 3 B train)
State CAP-FN-35 response to refueling bridge Rad Monitor alarms
Alert:
- Prevents fan start
- will not trip the fan