1
Q

State max capacity of new fuel vault

A

90,

81 for high enrichment assemblies

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

State basis for T.S. 3.9.11 for 23’ of water over fuel

A

removes 99% of the assumed 10% iodine gap activity released from the rupture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

State raise interlock for new fuel elevator

A

This prevents raising the elevator when loaded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

State the proximity switches for the upender

A
Carriage at RX
Carriage at Pool
Frame up
Frame Down
Gate valve
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Discuss the Refueling machine interlock over-ride features

A

SM and SRO agree to use
Refueling SRO directly supervises all actions
Each use of the interlock override is communicated to the CR
A spotter observes all movements
interlock override key needs to help in bypass
RFM operator need to monitor height/weight continuously during interlock override operation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

State what must happen if boron is found below the limits of the COLR during refueling (T.S. 3.9.1)

A

Immediately suspend core alterations
AND
Initiate boration at 30GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

State what must done if both SR NIs are not working and the audible count rate detector is not working (T.S. 3.9.2)

A

Immediately suspend core alterations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

State how long the RX must be subcritical for before moving fuel (T.S. 3.9.3)

A

80 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

State what must be done if containment closure can not be met during fuel moves (T.S. 3.9.4)

A

Immediately suspend core alterations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

State RHR requirement when refueling and cavity level is >23’ (T.S. 3.9.8.1)

A

At least 1 train of RHR must be in service other wise Immediately suspend core alterations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

State RHR requirements when refueling and cavity level is <23’ (T.S. 3.9.8.2)

A

Two loops have to be operable and one in service when <23’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

State when >23’ of water is required in the refueling cavity (T.S. 3.9.10)

A

When ever fuel is being moved in the vessel.
OR
Immediately suspend moving fuel assemblies or control rods

How well did you know this?
1
Not at all
2
3
4
5
Perfectly