Hydraulics Flashcards

1
Q

What is the power source for the rat switch?

A

Hot battery bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the conditions for rat deployment?

A

Both engine n2 below 50%
Aircraft is in the air
Min 80 kts airspeed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What min airspeed do you need to maintain for the rat to be effective?

A

130kts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What hyd system does the rap help power?

A

Center system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the function of the rat?

A

Provide essential flight controls using the center system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Can the rat be manually deployed on the ground?

A

Yes .. Press the switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How many hyd systems do we have?

A

3

Left, center , right

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How many hyd pumps on the left system?

A

2

One engine driven and one electric

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How many hyd pumps on the right system?

A

2

One engine driven and one electric

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How many hyd pumps on the center system?

A

3

2 electric and 1 air driven pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When does the adp kick in?

A

When it senses a low center system pressure or in times of great dmand

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What powers the adp?

A

Bleed air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How many total hyd reservoirs do we have?

A

3.

One for each system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What pressurizes the hyd reservoirs?

A

Bleed air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where is the center hyd pump heat exchanger located?

A

Right main wing tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where is the left hyd pump heat exchanger located?

A

Left main fuel tank

17
Q

Where is the right hyd pump heat exchanger located?

A

Right main fuel tank

18
Q

How much fuel do you need to have im the main tanks to run the electric hyd pumps on the ground?

A

4000 lbs

19
Q

When only one electrical generator is operating with both electric pump switches ON and both L and R system electric pumps operating, what happens to the number two center electric hyd pump?

A

It is inhibited

20
Q

During engine start, which electric hyd pump is inhibited during engine starts?

A

Left electric hyd pump

21
Q

What happens to right electric hyd pump any time flaps are out of zero on the ground?

A

on the ground, the right demand pump comes on continuously any time the flap lever is in the 1, 5, 15, or 20 position. This assures pressure to the normal brakes during takeoff.

22
Q

When do all the edp’s operate in auto mode?

A

When there is a demand..

23
Q

What does the reserve brakes isolation light mean?

A

The reserve brakes and steering isolation (ISLN) light illuminates to indicate the center hydraulic system is isolated

24
Q

Does the aircraft go into reserve brake mode automatically?

A

Yes

25
Q

What is the purpose of pressing the reserve brake switch?

A

Pushing the reserve brakes and steering switch signals the number one electric pump to operate regardless of the pump switch position. The switch also signals the control valves to move to the isolated position.

26
Q

What should the valve light do when you press the reserve brake switch?

A

It should extinguish now that the valves agrees with the switch commanded position.. If the light still stays on then the valve is not in agreement with how the system should be configured when in reserve brake mode

27
Q

If you are single gen, which electric hyd pump is inhibited?

A

Number 2 electric hyd pump in the center tank

28
Q

When does the quantity light come on?

A

Reservoir quantity is about half