General Specs for Overhaul Flashcards

1
Q

Garbage disposal rooms must include what type of waste cans?

A

2, 24 Gallon cans

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What spaces must have pulpers installed?

A

Wardroom, CPO Mess, and general mess sculleries.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Describe the pulper systems that are required.

A

Metal, Glass, and silverware should be automatically rejected to prevent damage. Seawater and freshwater should be included for pulping and flushing, and freshwater for wash down. Dishes should not be stored in room with pulpers.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Pulper diverter valves allow for what?

A

Pulped food to be discharged overboard or to the CHT system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When should pulled food be diverted to CHT, and when should it be discharge overboard?

A

Less than 12nm from US shore to CHT tank, greater than 12NM discharge to the sea

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How high off the deck must incinerators be welded?

A

4 inches high minimum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Incinerator rooms must have what type of ventilation?

A

Forced air or natural exhaust, but must always be negative pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What type of sprinklers should be installed in incinerator rooms?

A

Saltwater sprinklers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Can approved food waste pulpers be utilized for classified document destruction?

A

Yes!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What distance from shore must you be to pulp classified documents?

A

50 NM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Should classified documents be discharged to CHT Tanks or overboard?

A

Overboard only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What/where does the Oily Waste Separator discharge?

A

Processed is discharged overboard, above the waterline, and separated oil is discharged to the Waste Oil Tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What system determines if the Oily Waste Separator is effective?

A

Oil Content Monitor, located downstream from the OWS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Why is the overflow point of the Oily Waste Holding Tank located at the bottom of the tank?

A

The oil and water naturally separate, and the oil will rise. This will allow water to discharge before oil does

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

High level alarms in the Waste Oil and Oily Waste Holding tanks should sound how far in advance of overflow happening?

A

2 minutes prior to overflow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How high should lifelines be, and how far apart should stanchions be spaced?

A

42 inches high, 14 inches apart. If height is restricted, the minimum height should be 36 inches

17
Q

What is the maximum sag allowed in lifelines?

A

3/4” per foot, measured from stanchion to stanchion

18
Q

What is the maximum length allowed in lifeline openings protected by chain or rope?

A