General Specs for Overhaul Flashcards
Garbage disposal rooms must include what type of waste cans?
2, 24 Gallon cans
What spaces must have pulpers installed?
Wardroom, CPO Mess, and general mess sculleries.
Describe the pulper systems that are required.
Metal, Glass, and silverware should be automatically rejected to prevent damage. Seawater and freshwater should be included for pulping and flushing, and freshwater for wash down. Dishes should not be stored in room with pulpers.
Pulper diverter valves allow for what?
Pulped food to be discharged overboard or to the CHT system
When should pulled food be diverted to CHT, and when should it be discharge overboard?
Less than 12nm from US shore to CHT tank, greater than 12NM discharge to the sea
How high off the deck must incinerators be welded?
4 inches high minimum
Incinerator rooms must have what type of ventilation?
Forced air or natural exhaust, but must always be negative pressure
What type of sprinklers should be installed in incinerator rooms?
Saltwater sprinklers
Can approved food waste pulpers be utilized for classified document destruction?
Yes!
What distance from shore must you be to pulp classified documents?
50 NM
Should classified documents be discharged to CHT Tanks or overboard?
Overboard only
What/where does the Oily Waste Separator discharge?
Processed is discharged overboard, above the waterline, and separated oil is discharged to the Waste Oil Tank
What system determines if the Oily Waste Separator is effective?
Oil Content Monitor, located downstream from the OWS
Why is the overflow point of the Oily Waste Holding Tank located at the bottom of the tank?
The oil and water naturally separate, and the oil will rise. This will allow water to discharge before oil does
High level alarms in the Waste Oil and Oily Waste Holding tanks should sound how far in advance of overflow happening?
2 minutes prior to overflow