Fire Prot Flashcards

0
Q

Fidex system avail for?

A

Engine nacelles
Apu
Cargo comp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

How many engine fire det loops?

A

2 loops

Both loops must detect fire or ovht

Short in one loop? Sngle loop detect
L/R FIRE FAIL caution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

L/R FIRE FAIL caution?

A

Short or open circuit in one loop detected.

Switches to sngle loop detect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Engine extinguishing sys

How many bottles?

A

Located in aft equip bay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

L/R eng fire push?

A

FueL
BLEED AIR
Hydraulic SOV
Arms squibs ( both btls)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Engine bottles contain?

A

Halon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

BTL 1/2 ARMED PUSH TO DISCH LT?

A

Squib is armed and btl charged

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

APU fire on gnd?

A

Shuts down

After 5 sec , discharges btl

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

APU FIRE PUSH pressed in?

A

Btl armed push to discharge lt comes on

Apu squibs armed
Apu fuel SOV closes
Apu lcv closes

APU fire shutoff Relay is energized to shutdown APU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What type of fire detection in cargo

A

Optical sensors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How many optical smoke detectors in cargo bins?

A

FWD 3

AFT. 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How many cargo detectors to detect smoke?

A

2 cargo detectors must detect smoke for warning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Cargo smoke detector fault?

A

FIRE SYS FAULT status

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fire suppression for cargo departments?

A

1 hi rate discharge

1 lo rate discharge btl

Located inside rt belly fairing of main landing gear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Qty MLG OVHT DET loops?

A

Single loop per wheel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

CARGO SMOKE PUSH?

A

Arms fwd and aft squibs

Closes AC SOV valve

Heater off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Cargo btls located?

A

Inside rt belly fairing aft of main landing gear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Engine qty loops?

A

Dual loops - 2 bottles - 2 squibs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Apu qty loops , btl, squibs

A

Dual loops - 1 btl - 1 squib

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Cargo qty smk detectors- btls

A

Optical sensors -3 fwd, 2 aft

2 btls hi/ lo ( dischg simultaneously)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

MLG qty loops

A

1/ wheel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

THE FIDEX interfaces with

A

Engines

Nacelles

Cargo comp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Engine fire detection qty loops

A

Dual heat sens loops

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

How many loops to detect a fire?

A

2 needed to detect a fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Fault in one engine fire detect loop?

A

L/R FIRE FAIL caution

Switches to sngl loop detection

25
Q

APU FIRE FAIL caution?

A

Short circuit or open circuit in 1 loop

26
Q

APU how many loops?

A

Dual loops

Both loops needed to detect fire

27
Q

Cargo detector fault?

A

FIRE SYS FAULT status

switches to single detector ops

28
Q

Cargo fire bottles

A

2

Hi rate btl and lo rate btl

Fire simultaneously

Located inside rt belly fairing

29
Q

What arms aft and fwd cargo squibs?

A

Cargo smoke push

aft also closes ac sov and heater

30
Q

How many APU firex bottles?

A

1 APU bottel (1 squib)

32
Q

Which system is not part of fidex system?

A

LAV

33
Q

LAV fire detection / protection?

A

Ceiling mounted smoke detector

Waste compartment fire ext

34
Q

CARGO

btl armed push to disch

If lit green?

A

Squibs armed

Bottles charged

35
Q

LAV extinguishing components?

A

Ext bottle w/ dual dischg nozzle
(End of nozzles have heat sens capsule)

Temp sensor on inside of door to provide evidence of hi heat

36
Q

What happens when smoke detected on LAV?

A

Aural alarm sounds in LAV

EICAS SMOKE FWD(AFT) LAV

37
Q

Do both cargo bottles discharge simultaneously?

A

Yes

38
Q

Apu fire on gnd , fuel and bleed at SOV close .. After 5 seconds??

A

Fire btl discharges automatically

External horn blows

39
Q

Where do we have smoke detection?

A

Cargo

Lav

40
Q

What happens when the

ENG FIRE PUSH switch light is pressed

A

Switch lights. illuminate

Arms both SQUIBS

SOV fuel closes

SOV BLEED AIR

SOV HYDR

generator off-line

FADEC disables both ignition systems on the affected engine

41
Q

Does the APU shut down for a fire on the ground

In-flight

A

Yes!!

On the ground the bottles discharge in five seconds

In-flight the crew much discharge the bottle

42
Q

What happens when a cargo smoke warning is generated OR cargo smoke push switch light is pressed?

A

Heater shuts down

Air inlet us will be close

Air outlet SOV closes

( also ….. cargo smoke push switch light arms squibs)

43
Q

What actually fires the cargo extinguisher squibs??

A

The green bottle Armed push to discharge switch

44
Q

How many cargo bottles

A

2

One fastest charge one slow discharge

45
Q

The FIDEX Unit is used to monitor the…?… of the loops

A

Electrical resistance

46
Q

How many portable halon extinguishers and where?

A

3

Behind the copilot

Entrance storage compartment

Wardrobe closet

FOE.. fuel oil electric

47
Q

How many water extinguishers

A

1

Right aft bulkhead of Cabin

Used for wood paper and fabric

48
Q

Where is the FCU(fire control unit) located?

A

Under captains storage bin

49
Q

Cargo fire extinguishers discharge time?

A

Fast btl. 60 seconds

Slo bottle 60 minutes

50
Q

Fwd cargo push switch?

A

Only arms squibs

51
Q

APU shuts down automatically for a fire inflight and on ground!!

Whats the difference tho?

A

Ground.. fire btl auto fires after 5 seconds

In flight the crew must discharge

8-9 ch8 fire protection

52
Q

Cargo bay fires btls are where?

A

Rt wing fairing

8-14

53
Q

Dual loop systems?

A

Engines

APU

54
Q

Single loop systems

A

Main landing gear

55
Q

FIRE SYS OK ….is what type of message?

A

ADVISORY

56
Q

Push fwd cargo push swtch?

A

Only arms squibs

57
Q

If the fidec detects smoke in the after cargo Bay, Will it automatically shut off the cargo bay heater and close the intake and exhaust shut off valves?

A

Yes.. automatically

58
Q

Fire sys fault status?

A

One of the smoke detectors fails the built-in test

Now requiring only one smoke detector to Trip

59
Q

FIRE SYS FAULT status?

A

Loss of redundancy

Failed loop in the engine or APU … or failure of a cargo smoke detectors

60
Q

How many portable hand operated fire extinguishers?

A

3

Flight deck

Forward entrance stowage

Wardrobe closet

61
Q

What type of Halon?

A

Halon1211

62
Q

Halon 1211 is used for?

A

FOE

FIRE
OIL
ELECTRICAL