Electrical Flashcards
Each IDG consists of
A constant speed drive and a generator
Power for starting the APU is provided by
APU battery
Amber IDG Fault light
HOTLOP
hi oil temperature
Low oil pressure
IDG automatically disconnects when
Severe oil temp
Over torque
What happens if we lose the number 2 IDG
Interruption of first officer flight data and disengage the autopilot if connected to the fo’s side
The ADG continues to operate and supply power to the ADG bus until what airspeed
Until the airspeed decreases below approximate 135 kts
Can the ADG deployed on the ground
Automatic deployment is inhibited on the ground by a wait on wheels switch
Priority control of AC power distribution during normal operation
IDG one powers AC bus one
IDG two Powers AC bus two
Does transfer occur during a generator failure
Yes for any reason other than a fault on its associated bus it will automatically transfer the load from the failed I DG to the remaining operative IDG
What is the priority logic for AC buses one and two
On side IDG
APU generator
Opposite Side IDG
External power
What power sources are available for the service configuration
Either external power or the APU generator
What buses are powered in the service configuration
AC service bus
The ADG is automatically deployed if
AC bus one and two are off-line
Both AC generators are off-line
APU gen is not available
The ADG bus supplies power to
The AC Essential bus
Hydpump 3b
Flaps and slats .. Half speed
Pitch trim channel 2
Where is the external DC receptacle located on the aircraft
The 900 is not equipped with an external DC power receptacle
6-64
Each TRU has on internal cooling fan, when does it operate
Whenever AC power is supplied to the TRU
Main battery amp and volt
17 amp hour /24 volt nickel cadmium battery
APU battery amp and volt
43 amp hour. 24 V nickel cadmium battery
If on EICAS:
AC bus two caution
Gen two caution
AUTOXFR FAIL caution
??
Go to AUTOXFR fail, we probably have a short in AC bus two
(The other checklists direct us to reset generator$
Main battery charged by bus
APU battery charged by bus
Main battery is charged by AC bus one
APU battery is charged by AC service business
What items are on the DC utility bus
Right side reading lights
Load shed bus
How many ACPC’s
How many DCPC’s
1 ACPC
2DCPC
The APU generator is driven by
Directly by the APU gearbox
IDG automatically disconnected when
OVER OVER
over torque Overtemp
What type is our ADG
Wet ADG … Fly weights no oil
115v AC
What happens when the DC main tie closes
Dc utility bus shed
right side reading lights
What fire suppression systems are available at all times on the DC emergency bus
APU and engine fire bottles
Fuel and hydraulic SOV’s
Where are the circuit breakers located for the main and AP you battery direct buses
CBP5 in the afternoon equipment bay
What powers the DC emergency bus
The DC battery bus and the APU batt direct bus
Continuously
What is the backup for failure of TRU one or two
Main tie will close and operative TRU willpower
Failure of one Essentil TRU?
ESS tie connector closes
What will occur if we lose both Essential TRU’s
Cross tie closes
Where are the two DCPCs located
In the avionics compartment
If both essential TRU’s fail, what happens
The cross tie automatically closes to allow TRU 2 power Tru essential battery an emergency bus
ESS TRU2 transfer contactor?
In the event of multiple malfunctions
If TRU one or TRU two fails?
The main tie will close to connect to the operating TRU
What happens when both essential TRU’s fail?
The cross tie closes
TRU two now becomes power source
If essential TRU one or two failure?
ESS TIE closes
If complete loss of AC power Will The essential tie close?
Yes… To connect the DC essential bus to the battery bus for emergency power
If the DC service which is selected on,
The DC service bus is powered from the APU battery direct bus
How many circuit breaker panels
8
CBP one and two are located in the flight deck
CBP5 is located in the aft equipment compartment
CBP6 is located in the forward equipment compartment
CBP on the Galley Control Panel
CBP on the AC PC
To CBP’s on the DC PC
EMER POWER ONLYmsg?
Indicates the ADG has deployed
AC bus 1/2 caution?
Associated bus is not powered
Where is the main battery located
In the nose avionics compartment
ACPC?
AC POWER CENTER
AC service bus is normally powered from AC bus two..
On the ground?
Powered from the APU or external power
If power is restored by pressing thePWR XFR OVERRIDE button..what happens?
Restored IDG willpower AC bus one and two
However the ADG will continue to power The critical flight controls and the ADG bus
DC power is supplied by
4 TRU’s and two batteries
2 DCPC’s Located
Avionics compartment
What’s feeds the DC emergency bus
Both the battery bus and the APU battery direct bus
What is on the emergency bus
Hydraulic SOV
Engine fuel SOv
APU fuel SOV
Firex