FIRE Flashcards

1
Q

Four steps to FIRE

A

Find
Inform
Restrict
Extinguish/Escape

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Classes of fire

A

A. Carbonaceous, flammable solids (wood etc)

B. Flammable liquids (petrol, oil, paint)

C. Flammable gases, (natural gas, hydrogen, propane)

D. Combustible metals (sodium, Magnesium, Pottassium)

F. Cooking fats and oils

ELECTRICAL fires do not have a class, as electricity is the source of the fire. Isolate the electrical current and use an extinguisher developed for electrical use (CO2)

Additionally, LITHIUM fires, use Lithium extinghuisher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Extinguishers and their use (classes) / Advantages/Disadvantages

Water: A

A

Water: A

Advantages: Cools
Disadvantages: conducts electricity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Extinguishers and their use (classes) / Advantages/Disadvantages:
Foam: AB

A

A, Solids
B, Liquids

Advantages: Smothers the fire, and cools
Disadvantages: Conducts electricity, Messy

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Extinguishers and their use (classes) / Advantages/Disadvantages
Powder: ABC + electrical

A

A Solids
B Liquids
C Gases
+ electrical

Advantages: Multiple Uses
Smothers Fire
Disadvantages: Can re-ignite later from latent heat.
Powder will damage electrical
instillations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Extinguishers and their use (classes) / Advantages/Disadvantages
AFFF foam

A

Aqueous Film Foaming Foam
A and B

Advantages: 5 times more effective than regular foam
Disadvantages: Breaks down easily

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Extinguishers and their use (classes) / Advantages/Disadvantages
CO2: B, C and Electrical

A

B Liquids
C Gases
Electrical
Advantages: Quickly starves the atmosphere of oxygen
Disadvantages: Harmful to Human Life in small
compartments/ Large quantities (FFE
in ER)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Extinguishers and their use (classes) / Advantages/Disadvantages
Wet Chemical: A and F

A

A solids
F Fats and cooking oils

Advantages: Cools Chemicals with high flash points
(galley fires)
Disadvantages: Not suitable for electrical fires
Can cause corrosion to some metals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Extinguishers and their use (classes) / Advantages/Disadvantages
ARGON: D (combustable metals)

A

Used for Combustible metals such as LITHIUM

Advantages: used against and combustible metals
Disadvantages: Not used for other fire classes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Areas that can be causes of fire:

A

Self igniting rags/liquids in bins

Laundry lint

Galley operations

Crew hair straighteners etc

Electrical fire (overloading sockets, water on electrical instillations, Faulty wiring)

Machinery failure, Rags left on machinery

Bunkering procedures

Owners/Clients smoking

Aircraft fuel and accidents

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What document gives information on:

  1. Length of hoses, numbers of equipment?
  2. What is in a fire kit, and dimensions of Int. Shore Connection?
A
  1. LY3
  2. FSS (Fire Safety Systems) Code
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

For how long after hot works must we maintain a watch?

A

24 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which chapter of SOLAS speaks to Fire?

A

Chapter II

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How long should a BA Cylinder last?

A

1,200L / 30 Minutes of air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Monthly Checks of Firemans outfit

A
  1. Verify everything is in the correct locker
  2. Ensure Locker is clean, dry and accessible
  3. Ensure storage bags are undamaged and dry
  4. Visual check of firemans suit, ready to go fitted over boots, with smoke hood and gloves/socks
  5. Visual inspection of torch, belt, insulated ax, radios, helmets
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Monthly Checks of BA kit:

A
  1. Ensure locker is clean and dry, and accessible
  2. All equipment is in the correct locker
  3. Cylinder is secure and at at least 90% of the appropriate Pressure
  4. Straps open, All Equipment undamaged
  5. Check system for leaks by turning off air and waiting 1m
  6. Check Positive Pressure
  7. Test on demand valve Bypass
  8. Check Mask Spider is open
  9. Finally, Check the function of the Warning whistle (50Bar)
  10. Check Tally is clean and in place
17
Q

Procedure for donning BA kit

A
  1. Remove from locker
  2. Turn on and check pressure
  3. Switch off, check for any air leaks
  4. Put on outfit whilst waiting for leaks
  5. BA kit over outfit
  6. Pressure back on, ensure demand valve shut
  7. Check for Positive Pressure/Air leaks from mask
  8. Test Whistle
  9. Put smoke hood over head/Mask
  10. Helmet over smoke hood
  11. Pressure back on, tag given to OSC, Ready to Go
18
Q

Where may we find the Fire/Safety Plan?

A

Bridge
ER
Crew corridor/Crew Mess

Additional FSP, Muster list on the Gangway in W/P tubing, to assist non-fire fighting personnel who may board during a fir

19
Q

What is a BA system?

A

Any system designed to provide the wearer with fresh breathable air in an otherwise hostile environment

20
Q

What is an EEBD?

How much time should it give the wearer?

How many must all ships carry?

Where are they found?

A

Emergency Escape Breathing Device

10 Minutes

2

ER, Accomodation

21
Q

Which MGN speaks to Muster, Drills, On board training and instruction, and Decision Support Systems?

A

MGN 71

22
Q

How often do we partake in Drills?

A
  1. a) Fire- Monthly, 25% crew change
  2. b) Abandon Ship- Monthly 25% crew change

Both of these if a senior officer Member has changed out

  1. Enclosed space rescue - 2 months
  2. MOB, medical emergency, emergency steering - 3 months
  3. Security, 3 month OR change of master/25% crew change
  4. Bunker spill drill, before bunkering and 3 months

ANNUAL, catastrophic event

23
Q

If possible, we should boundary cool from how many directions?

A

6 Directions/Walls

24
Q

After setting off CO2 in a compartment to extinguish a fire, how long should we wait before opening any vents/doors?

A

24 hours

25
Q

Fire in the ER, Procedure

A

Find: CCTV, Call the ER, send two crew members with UHF radios

Inform: Call the Master, Sound the Fire Alarm, Make MAYDAY DSC alert/Call, Sat C if in A3, Consider raising Juliet Flag

Restrict: Muster all crew and PASSENGERS, close fuel shut offs, Close W/T and Fire doors, Close fire dampers/Ventilation to ER, Consider altering course after a position assessment, Consider shutting down Machinery

Extinguish: Start fire pumps, Begin actions under emergency plan in ships SMS, RESCUE CASUALTIES, Remain in Bridge until relieved of the watch by the master, or assist Master in resolution as per Muster List

26
Q

Sprinkler/Drenching systems: advantages/Disadvantages

A

Advantages: Can quickly cool fires
Disadvantages:
Require a lot of water, Can cause water damage
Has negative effects on Stability

27
Q

Hi Fog/ Ultra Fog
advantages/Disadvantages

A

Advantages:
Small droplets and fine mist smother and
cool
Safe for People and the environment

28
Q
A