Equipment and Facility Planning Flashcards
Planning team
Building rep, architect, fs manager/dietitian, builder, fs consultant
Flooring material
Kitchen - quarry, clay tiles
Dining - terrazzo, rubber, asphalt
Wall material
Ceramic tile
Equipment considerations: Metals
Gauge - thickness of metal (10-14 most common)
Aluminum = lightweight, durable
Stainless steel = heavyweight, durable
SS finishes #1 - dull, rough #2b - full finish, bright #2d - full finish, dull #4 - standard for fs #6 - soft finish #7 - glossy finish
Space recs
Main aisle - 5 ft
B/t workspaces - 3 ft
3.5-4 ft clearance for movable equipment or opening doors
Considerations for design
type of fs; labor and employee skill; maintenance schedule should be implemented to increase longevity of equipment; a record of maintenance should be available as well; equipment cleaned and regularly inspected; MSDS
Fryer
requires high amounts of energy–may be gas or electric
Tilting braising pan/tilting skillet pan
braising, boiling, grilling, or stewing
Steam jacketed kettle
functions like a double boiler, reduces risk of burning food
Mixers
table or floor models; used for mashed potatoes, batters, doughs, etc.
Refrigerators
reach in or walk in models
Sustainability: define
Capacity of being maintained for the long-term to meet present needs without risking the ability for future generations to also their needs
Sustainable food systems requirements
ecologically fit, economically achievable, socially acceptable
Sustainability: considerations
production, transformation, distribution, access, and consumption