EOP-1 Primary Script Flashcards
What do you do on the initial trip?
- Mark the time.
- Verify all rods inserted via lights and trip page.
- Verify Reactor Trip Alarm in.
- Verify Reactor Power Lowering.
Notify CRS “Reactor Trip at time xxxx, all rods fully inserted.”
CRS Says “Is the Reactor Tripped”
Yes, the reactor is tripped.
OR
Yes, the reactor is tripped; however I had to trip it from xx or take xx contingency.
CRS says: Is the Primary Coolant Pump Seal Cooling Adequate?
Yes, Primary Coolant Pump seal cooling is adequate.
OR
Yes, Primary Coolant Pump seal cooling is adequate, however: I had to take xx contingency.
CRS: Is Pressurizer Level between 20 and 85% trending toward normal?
Yes, Pressurizer Level is at xx% and slowly rising / lowering / stable.
CRS: Is the PCS at least 25F subcooled?
Yes, the PCS is xx degrees subcooled and rising/lowering/stable.
CRS: Is pressurizer pressure between 1650 and 2185 pounds and trending toward normal?
Yes, Pressurizer pressure is xx pounds and rising/lowering/stable.
CRS: Is at least 1 Primary Coolant Pump operating?
Yes, All four Primary Coolant Pumps operating.
OR
Yes, I have xx pump(s) operating.
CRS: Are loop delta-t’s less than 10F?
Yes, loop delta-t’s are each xxF and rising/lowering/stable.
CRS: Is the PCS at least 25 degrees subcooled.
Yes, the PCS is xx degrees subcooled and rising/lowering/stable.
CRS: Is containment pressure less than 0.85 pounds?
Yes, Containment pressure is xx pounds and rising/lowering/stable.
CRS: Is containment temperature less than 125F?
Yes, Containment Temperature is xxF and rising/lowering/stable.
CRS: Is containment pressure less than 0.85 pounds?
Yes, containment pressure is xx pounds and rising/lowering/stable.
CRS: Is instrument air header pressure greater than 85 pounds?
Yes, instrument air header pressure is xx pounds and rising/lowering/stable.
CRS: Is SIRW Tank greater than 25%?
Yes, SIRW tank level is xx% and rising/lowering/stable.
Post Verbal
CRS: Is at least one condensate pump operating?
Yes, two condensate pumps are operating
OR