Eng and inlet anti ice system Flashcards
purpose of the eng and inlet anti ice system
prevents ice build up on the inlet section
components of the eng and inlet anti ice system
anti-ice/start bleed valve
inlet anti ice valve
inlet thermal switch
are the solenoid closed or open when electrical power is supplied
closed
how to open the anti ice solenoid
turn on anti ice switches or deice master (will only open it as required by the ice detector)
three ways to anti ice the engine
vent bleed air into the swirl vanes and inlet guide vanes through the start bleed valve
vent bleed air into the airframe eng inlet through inlet anti ice valve
pump engine oil through the scroll vanes
what is the earliest the start bleed valve should close on start
80.5% Ng
What is the latest the start bleed valve should close unless eng anti ice is on or there is a loss of electricity
96.5% Ng
NEW*** three indications of a malfunctioning anti-ice/ start bleed valve
appearance or disappearance of eng anti ice on outside of rang specified in table
no anti ice on indication when switch is on
no rise in TGT when anti ice switch is on
what drives the inlet anti ice on advisory
when the thermal switch on the inlet hits 93 degree
freon bellows range
4-13 degrees 13 fully closed 4 fully open
do the anti ice switches allow inlet anti ice to turn on
yes, but the freon bellows may restrict air flow
indication of a malfunctioning inlet anti ice valve
inlet anti ice on advisory above 13 deg celsius
max loss of Q associated anti ice and inlet anti ice
18 and 49% respectively